Page 41 D633W101-BEJ Jan 05/2004
THRUST REVERSER SYSTEM -THERMAL INSULATION BLANKETS
The gaps at the edges of the blankets that are adjacent to the fire seals or some pressure seals are closed with filler and firewall sealant.
Training Point Information
You must open the thrust reverser to get access to the thermal insulation blankets.
The kapton faced blankets have several configurations which have blankets of different weights, thicknesses, sizes and shapes which also changes the location, pattern, quantity and type of the blanket fasteners on the inner wall. The kapton-faced blankets are not interchangeable between configurations.
Do not step on the blankets. Cracks can form through the kapton film skin moisture barrier which will allow the contamination and loss of the thermal insulation. Loose thermal insulation looks like a gray-white powder that escapes from cracks in the kapton film and hot-side cloth.
Hot, high speed air from a missing borescope inspection plug can damage or erode away the kapton skin, the ceramic cloth and the thermal insulation. Blankets with limited amounts of missing kapton skin, cloth and thermal insulation material should be repaired or must be replaced. Temporary repairs are available for the kapton-faced blankets. Different kinds of temporary repairs are given for the size and depth of the damage to the kapton faced blanket. One of the temporary repairs attaches a sheet of CRES sheet metal to the surface of the blanket with the same fasteners used to attach the blanket to the inner wall. Other temporary repairs seal the surface of a damaged blanket with adhesive. A kapton blanket with a temporary repair must be replaced within the time limits in the AMM with a serviceable replacement blanket or a blanket that has a permanent repair.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 发动机排气 Engine Exhaust PW 777 AIRCRAFT MAINTENANCE MANUAL(23)