Doc # 6.02.01 Page 27 
Rev. 4 09 Jan 2003
05-20-00 
Maintenance Checks 
AMM
%
%
%
DA 40 Series
100 hr items marked X* apply to US registered airplanes only  Interval  
Inspection Items  50  100  200  1000  Time  Initials  
23.  Examine the alternate static valve, if installed. Make sure that: S The valve is correctly attached. S The valve is not blocked. S The hoses are correctly attached.  X*  X  X  
24.  Lycoming version only: Lubricate the ignition switch: S See FAA AD 93-05-06 reference ACS/Gerdes Service Bulletin SB92-01-ACS, ignition switch lubrication/inspection.  X  
25.  Examine the compass. Make sure that: S The compass is correctly attached. S The fluid level is correct.  X  X  
26.  Examine the controls in the center console. Make sure that for each control lever: S There is full and free movement. S There is no unusual play. S The friction is correct. S The mixture lock-out operates correctly (Lycoming version only).  X  X  X  
27.  Examine the control cables in the center console: S Remove the retaining screws for the center console cover plate. S Lift the center console cover plate and visually examine the cables. Look specially for wear and kinks in the cables. S Lower the center console cover plate into the correct position, install the retaining screws.  X  X  X 
Page 28 Doc # 6.02.01 09 Jan 2003 Rev. 4
05-20-00 
AMM 
Maintenance Checks
%
DA 40 Series
100 hr items marked X* apply to US registered airplanes only  Interval  
Inspection Items  50  100  200  1000  Time  Initials  
28.  Examine the trim control in the center console. Make sure that: S There is full and free movement. S There is no unusual play.  X  X  X  
29.  If the autopilot system is installed, then examine the trim servo assembly. Look specially for: S Wear and corrosion. S Insecure attachment of servo. S Damaged, deformed, or worn out cardan shaft and chain gears. (Refer to Section 22-10).  X  X  X  
30.  Examine the front cockpit structure. Look for dis-bonding, delamination and damage, specially to these components: S The fuselage shells. S The firewall. S The floor. S The control bulkhead. S The fuel pipe channels. S The front main bulkhead. S The rear main bulkhead. S The inner faces of the front and rear closing ribs. S The front and rear seat crash elements.  X 
05-20-00 
Maintenance Checks 
AMM
D. Center Fuselage, Internal 
%
DA 40 Series
100 hr items marked X* apply to US registered airplanes only  Interval  
Inspection Items  50  100  200  1000  Time  Initials  
1.  Examine the fire extinguisher. Make sure that: S The fire extinguisher will release from the mounting bracket. S The fire extinguisher contents are full. Do a check of the extinguisher expiry date. (Refer to Section 26-00).  X  X  X  
 