21-52-00

Page 25 D633W101-BEJ Sep 05/2002

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CONTROL -PACK COOLING TEMP SENSORS

*
Condenser inlet temperature sensor (2)

*
Secondary turbine inlet temperature sensor.


The ASCPC and CTC pack discharge temperature sensors are interchangeable.
EFFECTIVITY BEJ ALL  21-52-00 
Page 26 
D633W101-BEJ  Sep 05/2002 

 

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CONTROL -PACK COOLING TEMP SENSORS

EFFECTIVITY BEJ ALL  21-52-00 
Page 27 
D633W101-BEJ  Jan 05/2002 


AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CTRL -MANIFOLD TEMP SENSORS

Purpose 
The mix manifold temperatures at the manifold outlet temperature sensors.  temperature mix manifold.  sensors There  monitor are four  air mix 
Physical Description 

The sensors are single element thermistor devices. The sensor housing has an external hex wrench fitting and threads for installation in the mix manifold.
Location
The sensors are in the top of the mix manifold. Open the flexible neoprene liner at the aft end of the forward cargo compartment to get access to the mix manifold area.
Training Information Point
The mix manifold temperature sensors are interchangeable. The mix manifold temperature sensors are also interchangeable with the cabin zone duct temperature sensors.
EFFECTIVITY BEJ ALL  21-52-00 
Page 28 
D633W101-BEJ  Jan 05/2002 

 

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CTRL -MANIFOLD TEMP SENSORS

EFFECTIVITY BEJ ALL  21-52-00 
Page 29 
D633W101-BEJ  Jan 05/2002 

 

777 AIRCRAFT MAINTENANCE MANUAL

THIS PAGE IS INTENTIONALLY LEFT BLANK

21-52-00

Page 30 D633W101-BEJ Jan 05/2002

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CTRL -RAM AIR INLET DOOR AND ACTUATOR

Purpose
The ram air inlet door controls the flow of ram air supplied to the dual heat exchanger. This is to control the amount of air used to cool the dual heat exchanger. This functions with other components to control air temperature from the pack.
BEJ ALL PRE SB 777-21-0059
Physical Description
The ram air inlet door is a two part assembly. The forward part has a hinge attached at a permanent position at the ram air inlet.
The aft part has a free hinge attached on the aft side of the forward part. The aft side of the aft part mounts on slide blocks.
The actuator turns a torque tube that attaches to the aft part of the door behind the hinge.
BEJ ALL POST SB 777-21-0059
Physical Description
The ram air inlet door is a two part assembly. The forward part has a hinge attached at a permanent position at the ram air inlet.
EFFECTIVITY
BEJ ALL

The aft part has a free hinge attached on the aft side of the forward part. The aft side of the aft part mounts on swing links.
The actuator turns a torque tube that attaches to the aft part of the door behind the hinge.
BEJ ALL
Location
The ram air inlet doors are on the bottom of the airplane forward of the ECS bay doors.
Functional Description
A close or open signal from the CTC operates the actuator motor in the necessary direction.
A rotary variable differential transformer (RVDT) in the actuator sends the position of the door to the CTC.
Training Information Point
When you change a component of the ram air inlet system, measure the closed position of the door. If it is necessary, adjust the actuator to get the correct measurement.
21-52-00

Page 31 D633W101-BEJ May 05/2003

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CTRL -RAM AIR INLET DOOR AND ACTUATOR

WARNING: MAKE SURE THAT PERSONNEL ARE CLEAR OF THE RAM AIR INLET DOOR, LINKAGE AND ACTUATOR BEFORE YOU DO THIS SPECIAL FUNCTION. POSSIBLE INJURY TO PERSONNEL CAN OCCUR.
The ram air inlet doors are normally open with the airplane on the ground. You use a MAT special function to close the ram air door if necessary.
EFFECTIVITY BEJ ALL  21-52-00 
Page 32 
D633W101-BEJ  Sep 05/2002 

 

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CTRL -RAM AIR INLET DOOR AND ACTUATOR

EFFECTIVITY BEJ ALL PRE SB 777-21-0059  21-52-00 
Page 33 
D633W101-BEJ  May 05/2003 

 

AIR CONDITIONING -PACK CLG AND MIX MANIFOLD TEMP CTRL -RAM AIR INLET DOOR AND ACTUATOR

EFFECTIVITY BEJ ALL POST SB 777-21-0059  21-52-00 
Page 34 
D633W101-BEJ  May 05/2003 

 

777 AIRCRAFT MAINTENANCE MANUAL

THIS PAGE IS INTENTIONALLY LEFT BLANK
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 空调 Air Conditioning(58)