Remove relay, R7437, from the P414, Left Power Distribution Center.

 (c)  
Close 6D34, PROBE HEAT IND L and 6D32, PROBE HEAT AUX PITOT L circuit breakers on the P6 Main Power Distribution Panel.

 (d)  
Open 7F23, LANDING GEAR DSP & CONT ALTN circuit breaker on the P7, Overhead Circuit Breaker Panel.

 (e)  
Make sure that the EICAS advisory message HEAT P/S L AUX does not show.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-31-00
 ALL  ú ú 03 Page 512 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (f)  
Make sure that the lower left pitot probe head temperature increases.

 (g)  
Close 7F23, LANDING GEAR DSP & CONT ALTN circuit breaker on the P7, Overhead Circuit Breaker Panel.

 (h)  
Open 6D34, PROBE HEAT IND L and 6D32 PROBE, HEAT AUX PITOT L circuit breakers on the P6, Main Power Distribution Panel.

 (i)  
Install relay, R7437, in the P414, Left Power Distribution Center.


 S 715-028
 (4)  Make sure that the lower left pitot probe strut heater operates:
 (a)  
Remove relay, R7435, from the P414, Left Power Distribution Center.

 (b)  
Close 6D34, PROBE HEAT IND L and 6D32, PROBE HEAT AUX PITOT L circuit breakers on the P6, Main Power Distribution Panel.

 (c)  
Open 7F23, LANDING GEAR DSP & CONT ALTN circuit breaker on the P7, Overhead Circuit Breaker Panel.

 (d)  
Make sure that the EICAS advisory message HEAT P/S L AUX does not show.

 (e)  
Make sure that the lower left pitot probe strut temperature increases.

 (f)  
Close 7F23, LANDING GEAR DSP & CONT ALTN circuit breaker on the P7, Overhead Circuit Breaker Panel.

 (g)  
Open 6D34, PROBE HEAT IND L and 6D32, PROBE HEAT AUX PITOT L circuit breakers on the P6, Main Power Distribution Panel.

 (h)  
Install relay, R7435, in the P414, Left Power Distribution Center.


 S 715-029
 (5)  Make sure that the lower left pitot probe heater operates on the ground with an engine on signal:
 (a)  
Remove relay, R7437, from the P414, Left Power Distribution Center.

 (b)  
Close 6D34, PROBE HEAT IND L and 6D32, PROBE HEAT AUX PITOT L circuit breakers on the P6, Main Power Distribution Panel.

 (c)  
Set the S1 switch on the YMLA003 ENG 2 N2 speed card in the forward electrical systems card file to TEST.

 (d)  
Make sure that the EICAS advisory message HEAT P/S L AUX does not show.

 (e)  
Make sure that the lower left pitot probe head temperature increases at a lower rate.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 30-31-00
 ALL  ú ú 02 Page 513 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (f)  
Set the S1 switch on the YMLA003 ENG 2 N2 speed card to NORMAL.

 (g)  
Alternative steps to do a check of the probe heater operation: 1) Set the S1 switch on the YMLA003 ENG 1 N2 speed card to


 TEST. 2) Measure the voltage at Pin B1 of Relay socket DR7435. 3) Make sure the voltage measurement is from 60 to 65 volts,
 with a digital multimeter on the AC scale. 4) Set the S1 switch on the YMLA003 ENG 1 N2 speed card to NORMAL.
 (h)  
Open 6D34, PROBE HEAT IND L and 6D32, PROBE HEAT AUX PITOT L circuit breakers on the P6 Main Power Distribution Panel.

 (i)  
Install relay, R7437, in the P414, Main Power Distribution Panel.


 H. Upper Right Pitot Probe Heat Test
 S 865-030
 (1)  
Close 6D35, PROBE HEAT IND R and 6D31, PROBE HEAT PITOT R circuit breakers on the P6, Main Power Distribution Panel.

 S 715-031

 (2)  
Make sure that the upper right pitot probe heaters operate:

 (a)  
Make sure that the EICAS advisory message HEAT P/S F/O shows.

 (b)  
Make sure that the upper right pitot probe temperature does not increase.
 