|-----------------------------------------------------------------------------| | ATA | SYSTEM MALFUNCTION | COMPUTER | RESET | | | | | PROCEDURE | |-----------------------------------------------------------------------------| | | | | seconds: | | | | | - For the MCDU1: on the | | | | | panel 121VU or panel 49VU,| | | | | C/B 11CA1. | | | | | - For the MCDU2: on the | | | | | panel 121VU, C/B 11CA2. | | | | | - For the MCDU3: on the | | | | | panel 121VU, C/B 11CA3. | | |-----------------------------------------------------------------------| | |FMGC malfunction | FMGC | On the panel 121VU or 49VU: | | | | | - open the FMGC 1 C/B 10CA1 | | | | | and close it after 10 | | | | | seconds. | | | | | If there is no reset of the | | | | | FMGC 1, do a reset of the | | | | | FMGC 2 on the panel 121VU: | | | | | - open the C/B 10CA2 and | | | | | close it after 10 seconds.| |-----------------------------------------------------------------------------|
**ON A/C 001-049, 051-099, 101-105, 201-299,
E. Communications
(1) Computer Reset Table
|-----------------------------------------------------------------------------| | ATA | SYSTEM MALFUNCTION | COMPUTER | RESET | | | | | PROCEDURE | |-----------------------------------------------------------------------------| | |COM CIDS 1+2 FAULT | CIDS |- Open the C/Bs in this | | | | | order: | | | | | on the panel 49VU, C/B 150RH| | | | | on the panel 121VU, C/B | | | | | 151RH | | | | |- After 10 seconds, close | | | | | the C/Bs in this order: | | | | | 151RH, 150RH. | | |-----------------------------------------------------------------------|
| | Frozen RMP | RMP | You must do a reset of all |
| | | | the RMPs, one after the |
| 23 | | | other. |
| | | | On the RMP control panel: |
| | | | - set the ON/OFF switch to |
| | | | OFF |
| | | | - after 5 seconds, set the |
| | | | ON/OFF switch to ON. |
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-00-00∞∞∞∞∞∞∞∞∞∞Page 236
Aug 01/05 CES
|-----------------------------------------------------------------------------| | ATA | SYSTEM MALFUNCTION | COMPUTER | RESET | | | | | PROCEDURE | |-----------------------------------------------------------------------------| | |-----------------------------------------------------------------------| | | Frozen FAP | Tape | On the panel 121VU, open | | | | reproducer | the FAP C/B 170RH. | | | | | - After 10 seconds, close | | | | | the C/B 170RH. | | | | | If unsuccessful: | | | | | on the panel 2000VU | | | | | - open the tape reproducer | | | | | /PRAM C/B 2RX. | | | | | After 10 seconds, close the | | | | | C/B. | |-----------------------------------------------------------------------------|
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 1(88)