 24-CONTENTS Page 5 Aug 01/05 R CES


 CHAPTER 24
__________
 ELECTRICAL POWER
 TABLE OF CONTENTS
_________________
 SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Signal to the GCU 2 Failure of the ENG/APU FIRE Panel A259 401-499, or its Wiring to the GCU 1 Failure of the ENG/APU FIRE Panel A261 401-499, or its Wiring to the GCU 2 Failure of the GCU 1 A263 401-499, Failure of the GCU 2 A265 401-499, Failure of the Generator Control A267 401-499, Unit 1 Failure of the Generator Control A269 401-499, Unit 2 Failure of the Auxiliary Status A271 401-499, Circuit of the BTC 1 Failure of the Auxiliary Status A274 401-499, Circuit of the BTC 2 Failure of the IDG 1 PMG Stator or A277 401-499, its Wiring Failure of the IDG 2 PMG Stator or A280 401-499, its Wiring Failure of the GCU 1 Air/Ground A283 401-499, Status Failure of the GCU 2 Air/Ground A285 401-499, Status Failure of the Generator Control A287 401-499, Unit 1 Failure of the Generator Control A290 401-499, Unit 2 Failure of the IDG 1 Exciter-Field A293 401-499, Wiring Failure of the IDG 2 Exciter-Field A296 401-499, Wiring Failure of the FAULT Light of the A299 401-499, ELEC/GEN 1 Pushbutton Switch (3XU1) Failure of the FAULT Light of the B202 401-499, ELEC/GEN 2 Pushbutton Switch (3XU2) Failure of an Opposite Channel of B205 401-499, the Generator 1 Channel Failure of an Opposite Channel of B208 401-499, the Generator 2 Channel Overcurrent on the GEN 1 Because B211 401-499, of a Failure of the BTC 1 Status Circuit Overcurrent on the GEN 2 Because B213 401-499, of a Failure of the BTC 2 Status
 24-CONTENTS Page 6 Aug 01/05 R CES


 CHAPTER 24
__________
 ELECTRICAL POWER
 TABLE OF CONTENTS
_________________
 SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Circuit Failure of the GLC 1 Control B215 401-499, Circuit Failure of the GLC 2 Control B218 401-499, Circuit Failure of the GLC 1 Contacts in B221 401-499, the Closed Position Failure of the GLC 2 Contacts in B223 401-499, the Closed Position Failure of the BTC 1 or its Status B225 401-499, Contact or Wiring Failure of the BTC 2 or its Status B227 401-499, Contact or Wiring IDG 1 Phase Reversal B229 401-499, IDG 2 Phase Reversal B233 401-499, Failure of the IDG 1 Exciter Field B237 401-499, Failure of the IDG 2 Exciter Field B240 401-499, Failure of the AC Current B243 401-499, Transformer of the IDG 1 Failure of the AC Current B246 401-499, Transformer of the IDG 2 Low Oil Pressure of the Integrated B249 401-499, Drive Generator 1 Low Oil Pressure of the Integrated B253 401-499, Drive Generator 2 IDG 1 Manual Disconnect B257 401-499, IDG 2 Manual Disconnect B261 401-499, Failure of the IDG 1 PMG Stator B265 401-499, Failure of the IDG 2 PMG Stator B268 401-499, Failure of the IDG 1 PMG Stator or B271 401-499, its Wiring to the GCU 1 Failure of the IDG 2 PMG Stator or B274 401-499, its Wiring to the GCU 2 Failure of the Bus between the ECU B277 401-499, 1 and the GCU 1 Failure of the Bus between the ECU B279 401-499, 2 and the GCU 2 Failure of the IDG 1 Servo Valve B281 401-499, or its Wiring Failure of the IDG 2 Servo Valve B284 401-499, or its Wiring Failure of the IDG 1 Servo Valve B287 401-499, or the Return Wiring Failure of the IDG 2 Servo Valve B290 401-499, or the Return Wiring Overload on the Electrical Network B293 401-499,
 24-CONTENTS Page 7 Aug 01/05 R CES


 CHAPTER 24
__________
 ELECTRICAL POWER
 TABLE OF CONTENTS
_________________
 SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ of the Generator 1 Overload on the Electrical Network B296 401-499, of the Generator 2 Failure of the BTC 1 Status B299 401-499, Sense-Circuit Failure of the BTC 2 Status C201 401-499, Sense-Circuit Failure of the IDG 1 Neutral C203 401-499, Feeder Failure of the IDG 2 Neutral C206 401-499, Feeder Failure of the GEN 1 Feeders or C209 401-499, the Current Transformer Assembly Failure of the GEN 2 Feeders or C212 401-499, the Current Transformer Assembly Failure of the Feeders Between the C215 401-499, IDG 1 and the GLC 1 Failure of the Feeders Between the C218 401-499, IDG 2 and the GLC 2 Failure of the Feeders Between the C221 401-499, IDG 1 and the GLC 1 Failure of the Feeders Between the C223 401-499, IDG 2 and the GLC 2 Failure of the GCU 1 Pin C225 401-499, Programming Failure of the GCU 2 Pin C227 401-499, Programming Failure of the GCU 1 POR Wiring C229 401-499, Failure of the GCU 2 POR Wiring C231 401-499, Failure of the IDG 1 Feeder or GCU C233 401-499, 1 POR Wiring Failure of the IDG 2 Feeder or GCU C236 401-499, 2 POR Wiring Failure of the POR neutral wiring C239 401-499, of the GCU 1 Failure of the POR neutral wiring C241 401-499, of the GCU 2 Failure of the APU generator AC C243 401-499, Current Transformer or its Wiring Failure of the APU Generator C245 401-499, Channel Failure of the Status Circuit of C248 401-499, the APU GLC APU Generator Overload C250 401-499, Short Circuits of the Feeders C252 401-499, between the APU Generator and the
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 1(14)