NOTE : As the GEN 2 was set to OFF because of a true failure, the fault
____
confirmation is not necessary.
4. Fault Isolation
_______________
A. If the fault symptom is identified by the CFDS message IDG 2 LOW OIL PRESSURE and the upper ECAM DU warning IDG 2 OIL LO PR:
NOTE : You can find this message with other CFDS fault messages. Do this
____
trouble shooting procedure first.
- do a check of the IDG2 oil level (Ref. AMM TASK 24-21-00-210-046).
(1) If the oil level is low:
- do a visual inspection of the IDG2 and external system (tubings, cooler) for oil leaks (Ref. AMM TASK 24-21-00-210-047).
(a) If you find no leak:
- add oil (Ref. AMM TASK 12-13-24-612-041).
(2) If the oil level is correct:
- do a check of the Differential Pressure Indicator (DPI) of the IDG2 (Ref. AMM TASK 24-21-00-210-046).
(a) If the DPI is extended:
- do the alternate procedure (Ref. TASK 24-21-00-810-816).
(b) If the DPI is not extended:
- do an inspection of the IDG2 filter element (Ref. AMM TASK 24-21-00-210-044).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page A223
201-299, 301-399, Aug 01/05 CES