 (1) If the wiring is not correct:

 - repair it.

 (2) If the wiring is correct:


 - replace the GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-000-001) and (Ref. AMM TASK 24-22-34-400-001).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 B. Do this operational test to make sure that the system operates correctly.
 (1) Aircraft Maintenance Configuration

 (a) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).

 (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).

 

 (2) On the ELEC panel 35VU:

 - push, release and push again the GEN 1 pushbutton switch (3XU1).

 (3) Do the operational test of the GPCU (Ref. AMM TASK 24-41-00-740-002).

 (4) Start the engine 1 (Ref. AMM TASK 71-00-00-710-003).


 C. Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the ECAM control panel:  On the lower ECAM display unit:
 - get the ELEC page.  - the correct electrical parameters of GEN 1 are shown and AC 1 busbar is supplied by GEN 1.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page 211
 201-299, 301-399, Aug 01/05 CES 5. Close-up


________
 A. Put the aircraft back to its initial configuration.
 (1) Stop the engine 1 (Ref. AMM TASK 71-00-00-710-028).

 (2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.

 (3) De-energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-862-002).

 

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page 212
 201-299, 301-399, Aug 01/05 CES

 TASK 24-20-00-810-806


 Loss of the Generator 1 (Pins D, E, F, R, P, N of BTC1 shorted to ground)
 1. Possible Causes
_______________
 - feeder

 - IDG1 feeders

 - IDG1 (4000XU)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 24-21-51-000-040 Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) AMM 24-21-51-400-040 Installation of the Integrated Drive Generator -IDG 1(2),(4000XU) AMM 24-41-00-740-002 Operational Test of the Ground power Control Unit (GPCU) AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from Engine 1(2) AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power
 AMM 31-60-00-860-001 EIS Start Procedure
 AMM 71-00-00-710-003 Engine Automatic Start
 AMM 71-00-00-710-028 Engine Shutdown
 ASM 24-22/02

 3. Fault Confirmation
__________________
 A. Test
 Not applicable.

 NOTE : As the GEN1 was set to OFF because of a true failure, the test
____
 confirmation is not necessary.

 4. Fault Isolation
_______________
 **ON A/C 001-049, 051-062, 101-105, 151-152, 201-205,
 A. If the fault symptom is identified by the maintenance message CHECK BTC1 PIN D, E, F, R, P, N SHORT TO GROUND and by the warning GEN1 FAULT on the upper ECAM display unit:
 - do a check of the feeder for short to ground between respectively: . the pins A/G, A/H, A/J of the GLC1 and the main bus
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page 213
 201-299, 301-399, Aug 01/05 CES . the pins A/M, A/L, A/K of the GLC1 and the pins A/D, A/E, A/F of the BTC1 . the pins A/R, A/P, A/N of the BTC1 and the pins A/N, A/P, A/R of the APU GLC (Ref. ASM 24-22/02)


 (1) If the wiring is not correct:

 - repair it.

 (2) If the wiring is correct:

 - do a check of the IDG1 feeders for intermittent short to ground between respectively the pins A/T1, B/T2, C/T3 of the IDG1 and the pins A/D, A/E, A/F of the GLC1.
 