┃ A~7-~'M" A321 ┃ ┃ ┃ ┃
┃ FLIGHT CREW OPERATING MANUAL ┃ ┃ ┃ ┃
┗━━━━━━━━━━━━━━━━┻━━━━━━━━━━━━━━┻━━━━┻━━━━━┛
Potable water is stored in a 200-liters tank in front of the wing box behind the forward
cargo compartment.
While airborne, the aircraft uses bleed air to pressurize the water system ; on the ground
it uses air from the service panel pressure port.
Potable water is piped to the galleys and lavatories. Manual shutoff valves isolate the
forward, mid <~ and aft washbasins from the water system. These valves, easily
identifiable by OPEN and SHUT legends, are under washbasins or toilet bowls.
The system can be filled or drained from the service panel at the bottom of the fuselage.
Indicators on the forward attendant's panel and the aft service panel show how much
water the water tank contains.
WA
HEA
DRAINING GROUND FILLING OVER FLOW
PORT PRESSURIZATION PORT PORT
PORT
WATER
QUANTITY
INDICATOR
CCM ALL
┏━━━━━━━━━━━━━━━━┳━━━━━━━┳━━━━━━━━━┓
┃I -~ A318 ┃WATER WASTE ┃1.38.10 P 3 ┃
┃ .*,,.8, ,, ~L,~ A319 ┃ ┃ ┃
┃ Lli,~ A320 ┃ ┃ ┃
┃ ┃ ┣━━━━┳━━━━┫
┃ A~7-~'M" A321 ┃ DESCRIPTION ┃SEQ 001 ┃REV 23 ┃
┃ FLIGHT CREW OPERATING MANUAL ┃ ┃ ┃ ┃
┗━━━━━━━━━━━━━━━━┻━━━━━━━┻━━━━┻━━━━┛
Wastewater from the galleys and from the sinks in the lavatories drains overboard through
two anti-iced drain masts.
The forward mast drains wastewater from the forward cabin; the aft mast drains it from
the aft cabin.
Differential pressure discharges the wastewater in flight, and gravity does so on the
ground.
FWD TOILETS
CCM ALL
┏━━━━━━━━━━━━━━━━┳━━━━━━━━━━━━━━┳━━━━━━━━━━━┓