4 ----.„.„.....,
Raccord en position visse Fitting in screwed position
1
14201008AAAAMA4001
AAAA
Validity : S / N 1 — 9999 Swivel fitting — Servicing
Figure 301 20-00-06Page 302
(BA) DEC 98
CABLES AND PULLEYS
MAINTENANCE PRACTICES
1. CHECK OF CABLES (Figure 201)
A. Procedure
1) Check all cables when passed over pulleys, in fairleads and winding areas.
2) Wipe a clean and dry cloth along the cable to detect broken wires.
3) Any lint or threads found after wiping shows the critical area ; if doubtful, investigate - see Figure 201 (1/2), by doing successive loops.
WARNING : WHENEVER MAINTENANCE CONDUCTED REQUIRES REMOVAL / INSTALLATION OF CABLES, ENSURE THAT CABLES ARE NOT CROSSED DURING REINSTALLATION.
4) Inspect the wear of cables - see Figure 201 (2/2), replace any cables with excessive wear.
5) Examine the surface of cables for rust or corrosion ; if rust or corrosion are found, replace the cables.
2. REMOVAL / INSTALLATION - CABLES (Figure 202)
A. Tools and consumable materials
- 3 toolings T700A2799000008
B. Removal of cables
CAUTION : IF A CORRECTIVE ACTION ON ELEVATOR TAB OR ITS CONTROL DOES NOT REQUIRE REMOVAL OF CABLES, OR IF THE CORRECTIVE ACTION IS ONLY PARTIAL (FWD OR REAR), IN ORDER TO PREVENT AN UNTIMELY UNWINDING OF THE CABLES, SET BLOCKING DEVICE (2) FOR CABLES REF. T700A2799000008 ON REAR SUPPORTS (3) AND FWD SPOOL (1) AND REAR SPOOL (4).