Do the steps that follow to do a test of the right actuator:
(a)
Make sure the R ENG FIRE switch on the pilots aft control stand, P8, is in the NORMAL position.
(b)
Open this circuit breaker on the main power distribution panel, P6, and attach a DO-NOT-CLOSE tag: 1) 6C2, FUEL COND CONT - R
(c)
Put the R FUEL CONTROL switch on the P10 quadrant control stand to the RUN position.
(d)
Make sure the right SPAR VALVE disagreement light goes off after the right engine fuel shutoff valve opens.
(e)
Put the R FUEL CONTROL switch on the P10 quadrant control stand to the CUTOFF position.
(f)
Make sure the right SPAR VALVE disagreement light comes on.
(g)
Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P6 panel: 1) 6C2, FUEL COND CONT - R
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-22-11
ALL ú ú 01 Page 406 ú Sep 28/01
A
757
MAINTENANCE MANUAL
S 864-014
(12)
Remove electrical power if it is not necessary (AMM 24-22-00/201).
S 414-024
(13)
Close the applicable left or right access panel, 551BB or 651BB (AMM 06-44-00/201).