F.
Procedure
S 864-075
(1)
On the P10 panel on the control stand, move the applicable fuel control switch to CUTOFF and attach a DO-NOT-OPERATE tag.
S 864-079
(2)
On the P10 panel on the control stand, make sure the applicable ENG VALVE and FUEL SPAR lights are not on bright.
NOTE: This shows that the valve is in the commanded position,
____ bright lights show that the valve is not in the commanded position.
S 014-080
(3)
Open the applicable engine fuel shutoff valve (spar valve) access panel, 551BB or 651BB.
S 864-081
(4)
Make sure the manual override handle on the valve is in the closed position.
NOTE: Do not move the valve to the closed position with your
____ hand. The valve must be closed electrically.
S 014-082
(5) Open the applicable fan cowl panel, 414AR or 424AR
(AMM 71-11-04/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-22-01
ALL ú ú 06 Page 417 ú Jun 20/97
ú ú ú ú ú ú ú
A
757
MAINTENANCE MANUAL
S 494-119
WARNING: MAKE SURE THE AREA IS CLEAR OF ALL FLAMMABLE MATERIAL AND
_______ EQUIPMENT OR DEVICES THAT CAN CAUSE FLAMES OR SPARKS. INJURY TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR.
(6)
Put a five-gallon fuel-resistant container below the fuel filter case drain plug on the applicable engine (Fig. 403).
S 034-084
(7)
Remove the smaller of the two engine fuel filter case drain plugs (AMM 71-00-03/201).
S 684-085
(8)
Permit the fuel to drain into the container until the quantity of fuel drainage becomes less than sixty drops per minute.
S 364-086
(9)
If the leakage does not decrease within ten minutes, do this procedure for the applicable valve: Adapter Shaft Alignment.
NOTE: The fuel shutoff valve (spar valve) has leakage.
____
S 864-087
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 燃油 CHAPTER 28 - FUEL 3(27)