26-15-0 Page 102 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. Aug 15/76
APU FIRE DETECTION SYSTEM - ADJUSTMENT/TEST
1. APU Fire Detection System Test
A. Prepare to Test
(1)
Provide power to the airplane and energize busses on load control center P6.
(2)
Ensure the following circuit breakers are closed on load control center P6:
(a)
APU (Fire protection detection)
(b)
Master Warning and Control
(c)
Deleted
(d)
Landing Gear Indicating Lights
(3)
Ensure the following circuit breakers are open on load control center P6:
(a)
Engine-1
(b)
Engine -2
(c)
Wheel Well-Wing-Body Overheat
(d)
Cargo smoke (Passenger/Cargo Convertible Airplanes only)
B. Test System
(1)
Attempt to pull APU fire switch on the fire protection module. The switch should remain locked.
(2)
Press override button under APU fire switch and pull switch. Lock should be released and switch pulled out.
CAUTION: DO NOT ROTATE SWITCH WHILE PULLED OUT. FIRE EXTINGUISHING BOTTLE MAY BE DISCHARGED.
(3)
Close fire switches.
(4)
Hold the overheat-fire test switch to the overheat position. No engine fire indications should be presented; the APU detector inoperative light should illuminate.
(5)
Return the overheat-fire test switch to the off position.
(6)
Hold the overheat-fire test switch to the fire position. The following warning indications should be presented:
(a)
Both red fire warning lights on P7 should be illuminated.
(b)
The APU fire switch handle should be illuminated.
(c)
The APU fire switches should be unlocked. Verify by pulling out switch.
CAUTION: DO NOT ROTATE SWITCH WHILE PULLED OUT.
(d)
The fire bell in the control cabin should sound with a steady ringing.
(e)
The horn and fire warning light in the right main wheel well should go on and off at a 60 cpm rate.
(7)
While the lights are illuminated, position the lights test switch on the P2 panel to DIM and then back to BRT. The master fire warning lights should dim and then return to their original brightness.
(8)
Test fire bell and horn silencing and extinguishing of fire warning lights on P7 by pressing switches at each of the following stations:
5C8
Apr 01/97 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 26-15-0 Page 501
NOTE: Release the overheat-fire test switch after silencing and again hold it to the fire position to reactivate bell and horn for next station tested. Fire warning light on remote APU control panel should remain illuminated after bell and horn are silenced.