(4) The lower extension lead has:
- One rigid metal tube (Con-o-clad), equipped at each end with a mobile elbow-connector for connection to the main junction box assembly, and to the three-probe thermocouple lead assembly.
(5) The main junction box assembly has:
- Two rigid metal tubes (Con-o-clad), each equipped at one end with a mobile elbow-connector to the related two-probe lead assembly, and at the other end to a junction box. The junction box is equipped with two receptacles connectors for connection to the extension leads and one interface receptacle connector.
C. The electromotive force is averaged first in each of the individual lead assembly (2 probes and 3 probes), then in the main junction box assembly at the level of the interface connector. The resultant averaged electromotive force is then sent to the ECU through the CJ13 harness and the HJ13 harness.
2. EGT indication
______________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 003)
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 003A)
**ON A/C ALL
The EGT indication appears on the upper display unit of the ECAM system.
The ECAM provides the EGT indication :
- in analog form thru a pointer which deflects in front of a dial,
- in digital form, in the lower section of the dial.
The indication is normally green.
The index is displayed in amber above 915 deg. C (or above 725 deg. C during
start sequence).
The index and the numerical value become red above 950 deg. C, the MASTER
CAUT light comes on accompanied by the single chime, the following messages
appear on the ECAM :
- ENG 1(2) EGT OVERLIMIT
- THR LEVER 1(2)...BELOW LIMIT
If the EGT has exceeded 950 deg. C:
- the maximum value reached is memorized,
F 『 EEFF : ALL E Page 477-20-00
E E Aug 01/05 E E ECES E F 『 E C F M E E E
E 56-5B E
Upper Display Unit of the ECAM System - EGT Indication
Figure 003
F 『R EEFF : 001-049, 051-099, 101-105, 151-199, E Page 577-20-00
E E201-299, 301-302, May 01/05 E E ECES E F 『 E C F M E E E E 56-5B E
Upper Display Unit of the ECAM System - EGT Indication
Figure 003A
F 『R EEFF : 106-149, 303-399, 401-499, E Page 677-20-00
E E Aug 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
- a small red line remains positioned on the analog scale, at that value (max pointer). The red line will disappear after a new take off or maintenance action through the MCDU. Above 970 deg. C the messages displayed on the ECAM become:
- ENG 1(2) EGT OVERLIMIT
- THR LEVER 1(2)...IDLE
- ENG MASTER 1(2)...OFF
F 『 EEFF : ALL E Page 777-20-00
E E May 01/05 E E ECES E
R
R
R
F 『
E C F M E
E E
E 56-5B E
E E
T495 THERMOCOUPLE - REMOVAL/INSTALLATION
________________________________________ TASK 77-21-10-000-008 Removal of the Upper Extension Lead
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs No specific caps No specific warning notice
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance 78-36-00-010-040 Opening of the Thrust Reverser Doors 77-21-10-991-303 Fig. 401