• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 17:07来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

___________________________________________________
 TASK 75-31-00-820-001
 Adjustment of the Reference CLOSED Position of the VBV System
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific warning notice
 No specific access platform 1.5 m (4 ft. 11 in.)
 856A2501 1 WRENCH - VBV MANUAL CONTROL
 856A2664 1 GAGE, SETTING - VBV DOORS

 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
 71-13-00-410-040 Closing of the Fan Cowl Doors
 72-23-00-000-027 Removal of the Fan Duct Panels
 72-23-00-400-027 Installation of the Fan Duct Panels
 75-31-20-000-002 Removal of the Bleed Valve Stop Mechanism
 75-31-20-400-002 Installation of the Bleed Valve Stop Mechanism
 75-31-30-000-001 Removal of a VBV Inter-connecting Flexible Shaft

 (Typical). 75-31-30-400-001 Installation of a VBV Inter-connecting Flexible Shaft (Typical) 78-30-00-081-041 Make the Thrust Reverser Serviceable after Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance
 78-36-00-010-040 Opening of the Thrust Reverser Doors
 78-36-00-410-040 Closing of the Thrust Reverser Doors
 75-31-00-991-300 Fig. 501

 F 『 EEFF : ALL E Page 50175-31-00
 E E Feb 01/98 E E ECES E 3. Job Set-up

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


__________ Subtask 75-31-00-941-061
 A. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU:

 (a) Put a warning notice to tell persons not to start the engine.

 (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3) On the overhead maintenance panel 50VU:

 (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b) Put a warning notice to tell persons not to energize the FADEC 1(2).

 


 Subtask 75-31-00-010-062
 B. Get Access
 (1) Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR

 (2) Put the access platform in position. Subtask 75-31-00-040-056

 C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041). Subtask 75-31-00-010-064


 D. Get Access
 (1) Open the thrust reverser doors (Ref. TASK 78-36-00-010-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
 F 『 EEFF : ALL E Page 50275-31-00
 E E Feb 01/98 E E ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 (2) If applicable, remove the fan duct panels (Ref. TASK 72-23-00-000-027).
 4. Procedure
_________
 (Ref. Fig. 501/TASK 75-31-00-991-300) Subtask 75-31-00-820-050
 A. Adjustment of the Reference CLOSED Position of the VBV System
 (1) Adjust the reference CLOSED position of a VBV door (TYPICAL).

 (a) If applicable, disengage the flexible shafts ends from the VBV door sockets (Ref. TASK 75-31-30-000-001).

 (b) Turn the flexible shaft socket of the ballscrew actuator by hand or with WRENCH - VBV MANUAL CONTROL (856A2501G01) to completely close the VBV door.

 (c) Install the GAGE, SETTING - VBV DOORS (856A2664G01) as follows:

 (d) Turn the flexible shaft socket to open the VBV door until the GAGE, SETTING - VBV DOORS (856A2664G01) yoke engages on the flexible shaft socket.

 (e) Remove the GAGE, SETTING - VBV DOORS (856A2664G01) after installation of the flexible shafts (Ref. TASK 75-31-30-400-001).

 (f) If applicable, use the same procedure to adjust the other VBV doors reference CLOSED position.

 

 (2) Set the VBV stop mechanism to the CLOSED position as follows:

 (a) Disengage the flexible shafts ends from the master VBV door and ballscrew actuator (Ref. TASK 75-31-30-000-001).

 (b) With the WRENCH - VBV MANUAL CONTROL (856A2501G01), close the master VBV door and ballscrew actuator.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR 空气(38)