ON and END light go out. At the refuel couplings the light goes out to indicate to the
ground personnel that hoses can be disconnected.
Applicable to:
MANUAL REFUELING
DETERMINE FUEL QUANTITY IN EACH TANK
Respect distribution in accordance with applicable REFUEL DISTRIBUTION graph .
A330/A340 FLIGHT CREW
OPERATING MANUAL
PERFORMANCE
LOADING
FUEL
A330/A340 FLEET PER-LOD-FUL P 12/24
FCOM 19 AUG 10
Note: To refuel the trim tank, one of these conditions must be fulfilled.
the two inner ‐ tank inlet valves are open.
‐ both inner tank quantities are each greater than 14 000 kg.
‐ one inner tank quantity is greater than 14 000 kg and the other inner tank inlet valve is
open.
REFUEL VALVES..................................................................................................................... SHUT
REFUEL VALVES (tank(s) to be filled)....................................................................................OPEN
Note: Because the Fuel Control and Monitoring System (FCMS) does not have control of all the
tanks, the END light will flash.
MODE SELECT.................................................................................................................... REFUEL
REFUEL VALVES (tank(s) to be filled)....................................................................................OPEN
FUEL QTY..........................................................................................................................MONITOR
 When the tank contents reach the required level :
Corresponding REFUEL VALVES......................................................................................SHUT
MODE SELECT.......................................................................................... OFF and GUARDED
REFUEL VALVES...................................................................................NORM and GUARDED
Applicable to: ,
MANUAL REFUELING
DETERMINE FUEL QUANTITY IN EACH TANK
Respect distribution in accordance with applicable REFUEL DISTRIBUTION graph .
Note: To refuel the trim tank, one of these conditions must be fulfilled.
‐ the two inner tank inlet valves are open.
‐ both inner tank quantities are each greater than 14 000 kg.
‐ one inner tank quantity is greater than 14 000 kg and the other inner tank inlet valve is
open.
REFUEL VALVES..................................................................................................................... SHUT
REFUEL VALVES (tank(s) to be filled)....................................................................................OPEN
Note: Because the Fuel Control and Monitoring System (FCMS) does not have control of all the
tanks, the END light will flash.
MODE SELECT.................................................................................................................... REFUEL
FUEL QTY..........................................................................................................................MONITOR
 When the tank contents reach the required level :
Corresponding REFUEL VALVES......................................................................................SHUT
MODE SELECT.......................................................................................... OFF and GUARDED
A330/A340 FLIGHT CREW
OPERATING MANUAL
PERFORMANCE
LOADING
FUEL
A330/A340 FLEET PER-LOD-FUL P 13/24
FCOM 19 AUG 10
REFUEL VALVES...................................................................................NORM and GUARDED
GROUND FUEL TRANSFER
Applicable to:
A ground transfer is possible from tank to tank, except to the trim tank.
 On cockpit overhead FUEL panel :
PUMPS (of the tanks not to be defueled)................................................................................ OFF
PUMPS (of the tanks to be defueled)........................................................................................ ON
X-FEEDS (of the tank to be defueled)....................................................................................... ON
 On refueling control panel :
REFUEL VALVES (of tanks not to be filled)..........................................................................SHUT
REFUEL VALVES (of tanks to be filled)................................................................................OPEN
MODE SELECT..................................................................................................................REFUEL
TRANSF VALVE.................................................................................................................... OPEN
Note: The TRANSF VALVE switch opens the left aft transfer valve only if ENG 2 main pump
is on, and opens the right aft transfer valve only if the ENG 3 main pump is on.
 