曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
container/pallet).
ULD ATA NAS 3610 IATA Allowable MGWMaximum number
lb kg Forward Aft Bulk
Half-size LD3 2K2 E/G 3 500 1 587 14 12
Half-size LD1 2K2 C/H 3 500 1 587 7 6
60.4 × 61.5 in 2K3 X/G/E 3 500 1 587 14 12
60.4 × 61.5 in 2K3 H 3 500 1 587 7 6
Full-size LD6 2L2 F 7 000 3 174 7 6
60.4 × 125 in 2L3/2L4 F 7 000 3 174 7 6
88 × 125 in 2A1/2A2/2A3/2A4/2A6 F 10 200 4 626 4 4
96 × 125 in 2M1/2M2/2M3 F 11 250 5 103 4 4
CARGO DOORS OPERATION
Applicable to: ALL
NORMAL OPERATION
OPENING
On door
ACCESS DOOR OPERATING HANDLE................................................................ RELEASE
Push handle flap inward.
DOOR........................................................................................................................ UNLOCK
Move door operating handle upward from LOCKED to UNLOCK position.
A330/A340 FLIGHT CREW
OPERATING MANUAL
PERFORMANCE
LOADING
CARGO LOADING
A330/A340 FLEET PER-LOD-CGO P 3/8
FCOM 19 AUG 10
Indicator flags at the lower part of the door move out from the door contour. This gives a
visual indication that the cargo door is unlocked.
DIFFERENTIAL PRESSURE.......................................................................................CHECK
WARNING Do not operate the latching handle if the red indicator light flashes as an
overpressure exists in the cargo hold.
DOOR...................................................................................................................... UNLATCH
Press the pushbutton on the latching handle, then pull the handle down to the unlatched
position.
On door service panel
SERVICE PANEL ACCESS DOOR...............................................................................OPEN
LEVER OF MANUAL SELECTOR VALVE...................................................HOLD ON OPEN
The yellow hydraulic system is pressurized (YELLOW ELEC PUMP energized).
Operation of the flight controls is inhibited.
When the door is fully open (green light on the service panel is on) :
LEVER OF MANUAL SELECTOR VALVE..............................................................RELEASE
When released, the lever returns to the neutral (STOP) position and shuts down the electric
pump after a 10 s delay.
CAUTION Check that the lever has reached the neutral position and the pump
operation has stopped. Continuous operation leads to a pump overheat.
CLOSING
On door service panel
LEVER OF MANUAL SELECTOR VALVE.................................................HOLD ON CLOSE
At first the lever locks in an intermediate position, maintaining a pre-set pressurization to
prevent the door from dropping open. The operator can then move the lever to CLOSE and
the door closes. When it is fully closed, the lever returns to the neutral position and shuts
down the electric pump.
Ensure that green indicator light goes out.
When the door is fully closed :
LEVER OF MANUAL SELECTOR VALVE....................................................... RELEASE
Release within 1 min after door closure
On door
DOOR....................................................................................................... LATCH AND LOCK
Push the latching handle back into its recess. Push the door locking handle downwards
to the locked position. When the door is locked, the cargo doors indication on ECAM
extinguishes and the handle flap mechanism locks the operating handle.
A330/A340 FLIGHT CREW
OPERATING MANUAL
PERFORMANCE
LOADING
CARGO LOADING
A330/A340 FLEET PER-LOD-CGO P 4/8
FCOM 19 AUG 10
On door service panel
ACCESS DOOR...........................................................................................................CLOSE
AUXILIARY OPERATION
In case of an electrical failure or if the electric pump fails, the operator can open or close the doors
by working the hand pump.
HAND PUMP OPENING
On door
DOOR........................................................................................................................ UNLOCK
Unlock the operating handle as if for normal operation.
On door service panel
SERVICE PANEL ACCESS DOOR...............................................................................OPEN
LEVER OF MANUAL SELECTOR VALVE...................................................HOLD ON OPEN
On ground service panel
HAND PUMP...........................................................................................................OPERATE
The door opens.
When the door is fully opened (green light on the service panel is on or sudden
increase of force to operate the hand pump) :
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
A330/A340机组操作手册 FLIGHT CREW OPERATING MANUAL FCOM 5(102)