• 热门标签

当前位置: 主页 > 航空资料 > 飞行资料 >

时间:2010-09-27 07:52来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

• Check that GEN 1 and 2 OFF caution messages go out;
• Check that EMER PWR ONLY warning message goes out.
(31) ADG, PWR TXFR OVERRIDE switch ............................................................... Press
• To restore normal power supply.
• Check that all indications return to normal.
(32) ADG DEPLOY CONT – AUTO circuit breaker (2N6)......................................... Close
• The hydraulic 3A switch is normally set to ON and 3B switch is normally set to
AUTO.
On airplanes 5301 to 5407:
CAUTION
On landing, with the ADG deployed, use gentle deceleration to
preclude the ADG from swinging forward and damaging the
fuselage.
IN-FLIGHT CHECKS
Air-Driven Generator Checks
Vol. 1 09−02−6