• Check that GEN 1 and 2 OFF caution messages go out;
• Check that EMER PWR ONLY warning message goes out.
(31) ADG, PWR TXFR OVERRIDE switch ............................................................... Press
• To restore normal power supply.
• Check that all indications return to normal.
(32) ADG DEPLOY CONT – AUTO circuit breaker (2N6)......................................... Close
• The hydraulic 3A switch is normally set to ON and 3B switch is normally set to
AUTO.
On airplanes 5301 to 5407:
CAUTION
On landing, with the ADG deployed, use gentle deceleration to
preclude the ADG from swinging forward and damaging the
fuselage.
IN-FLIGHT CHECKS
Air-Driven Generator Checks
Vol. 1 09−02−6
REV 73, May 14/08