NOTE
Anticipate elevator out of trim situation when disconnecting the
autopilot.
(1) Autopilot ....................................................... Disconnect
(2) AFCS SEL 1(2) switch
(centre pedestal) ..................................................Select to operative AFCS channel.
Check AFCS 1 (2) INOP status
message on.
(3) FDs and autopilot .............................................. Engage and monitor operation.
Retrim as required.
FD annunciator flag displayed on both PFDs:
Yes
(4) Flight control panel XFR
switch.............................................................Press to transfer to operable side.
− END −
No
Sensor failure indicated (red line across affected flight director mode annunciator):
Yes
(4) Flight control panel affected
mode switch..............................................Deselect
− END −
No
(4) No further action required.
END
ABNORMAL PROCEDURES
Automatic Flight Control System
Vol. 1 05−06−4
REV 69, Jun 04/07
CL−604 Operating Manual
PSP 604−6
1. AUXILIARY POWER UNIT
A. APU Load Control Valve Fails to Close
Indication: APU LCV FAIL caution message and APU LCV FAIL light on.
(1) BLEED AIR, 10TH STAGE, L
switch/light .......................................................Press out to close left 10th stage bleed
valve.
Check L CLOSED light on.
(2) BLEED AIR, 10TH STAGE, ISOL
switch/light .......................................................Press out to close 10th stage isolation
valve.
Check 10TH ISOL OPEN light
out.
(3) AIR-CONDITIONING, L PACK
switch/light .......................................................Press out Check L PACK OFF light on.
Above 40,000 feet:
Yes
(4) ANTI-ICE, COWL L
switch/light .................................................Press in to select cowl anti-ice ON.
Check L COWL A/ICE ON
advisory message on.
− END −
No
(4) No further action required.
END
ABNORMAL PROCEDURES
Auxiliary Power Unit
Vol. 1 05−07−1
REV 66, Feb 01/07
CL−604 Operating Manual
PSP 604−6
1. AUXILIARY POWER UNIT (CONT'D)
B. APU Low Oil Pressure
Indication: APU OIL PRESS caution message on and APU automatically shuts down.
APU is supplying bleed air for air-conditioning:
Yes
(1) Air-conditioning......................................... Transfer to engine bleeds.
(a) BLEED AIR, 10TH
STAGE R switch/light ........................Press in to open right valve.
Check the following:
• R 10TH CLOSED light out.
• APU LCV OPEN light out.
(b) BLEED AIR, 10TH
STAGE ISOL switch/light.................Press out to close isolation valve.
Check the following:
• 10TH ISOL OPEN light out.
• APU LCV OPEN light on.
(c) BLEED AIR, 10TH
STAGE L switch/light .........................Press in to open left valve and close
APU load control valve.
Check the following:
• L 10TH CLOSED light out.
• APU LCV OPEN light out.
(d) BLEED AIR, APU LCV
switch/light .......................................Press out to match APU load control
valve closed position.
No
(1) APU, PWR FUEL switch/light..........................Press out
(2) Do not restart APU.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
庞巴迪挑战者604操作手册 Operating Manual 1(120)