two minutes, to dissipate heat and stabilize internal operating
temperatures.
Taxi time at 70% N2 or below may be credited in the two minute
cool-down period.
If ITT rises above 350°C following engine shutdown, carry out an
engine motoring cycle immediately to reduce ITT.
NORMAL PROCEDURES
Shutdown
Vol. 1 04−09−2
REV 66, Feb 01/07

CL−604 Operating Manual
PSP 604−6
1. SHUTDOWN (CONT'D)
A. Shutdown Check (Cont’d)
(6) FUEL, L and R BOOST PUMP
switch/lights .....................................................Press out to turn both boost pumps off.
Check the following:
• L and R BOOST PUMP ON
lights out.
• L and R BOOST PUMP
INOP lights on.
• L and R FUEL PUMP ON
advisory messages out.
• FUEL LO PRESS caution
message is annunciated for
the engine that now has
been shutdown.
(7) Fuel system check valve
operation ........................................................ Complete 1 the test initiated before
engine start.
After 2 minutes, if FUEL LO PRESS caution message is still not displayed for the
non-operating engine:
(a) Dry motor..............................................Accomplish for maximum of 30 seconds
on the non-operating engine.
Applicable FUEL LO PRESS
caution message should be
displayed during motoring as
the residual fuel pressure is
reduced.
CAUTION
Absence of the FUEL LO PRESS caution message during this
check is an indication that the fuel feed check valve has failed in
the open position.
(8) Other engine...................................................Shutdown
(9) Thrust levers............................................................. Set to SHUT OFF.
NORMAL PROCEDURES
Shutdown
Vol. 1 04−09−3
REV 74, Nov 07/08

CL−604 Operating Manual
PSP 604−6
1. SHUTDOWN (CONT'D)
A. Shutdown Check (Cont’d)
(10) Fuel crossflow valve operation ..............................Verify 2
(a) FUEL, L TO AUX XFLOW
switch/light ................................................. Press in to open left crossflow valve.
Check L TO AUX XFLOW ON
light on.
(b) FUEL, L TO AUX XFLOW
switch/light ...............................................Press out to close left crossflow valve.
Check L TO AUX XFLOW ON
light out.
(c) FUEL, R TO AUX XFLOW
switch/light ................................................. Press in to open right crossflow valve.
Check R TO AUX XFLOW ON
light on.
(d) FUEL, R TO AUX XFLOW
switch/light ...............................................Press out to close right crossflow valve.
Check R TO AUX XFLOW ON
light out.
(11) PASS SIGNS, NO SMKG and
SEAT BLTS switches ...........................................Select to OFF.
(12) ANTI-ICE, WING switch .......................................Select to OFF.
(13) ANTI-ICE, COWL
L and R switch/lights .......................................Press out to select cowl anti-ice off.
(14) ANTI-ICE, WSHLD/WIND
L and R switches ..................................................Select to OFF.
(15) BEACON switch (if installed)................................Select to OFF.
(16) NOSE STEER switch ...........................................Select to OFF.
NORMAL PROCEDURES
Shutdown
Vol. 1 04−09−4
REV 74, Nov 07/08
CL−604 Operating Manual
PSP 604−6
1. TERMINATING
A. Securing Check
The following procedures will be performed when the airplane is to be left unattended or
handed over to maintenance personnel, after all the passengers have deplaned.
(1) PARKING BRAKE ....................................... As required Ensure that chocks are in
place before releasing parking
brake.
(2) IRS selectors ............................................................ Set to OFF.
(3) THRUST REVERSER, L and R
switches................................................................Select to OFF.
(4) EXTERNAL LTS switches ....................................Select all to OFF.
(5) EMER LTS switch ................................................Select to OFF.
(6) Hydraulic pump switches......................................Select all to OFF.
(7) AC POWER, APU GEN switch.............................Select to OFF/RESET.
If external power is in use:
(7) EXT POWER, AC switch/light .........................Press out Check IN USE light out.
(8) APU................................................................Shutdown
(a) APU, START/STOP switch/light..............Press out to shutdown the APU.
 