same way that you previously called the ECAM ELEC page.
ELECTRICAL MENU
Abnormal operation (C) 34/54
We will now assume that all the ECAM pages of the
secondary failures have been reviewed. As you cleared
the last one, memo messages appeared on the E/WD.
The green RAT OUT memo message confirms that the
RAT is no longer stowed.
The green EMER GEN memo message indicates that
the emergency generator is running and supplying the
system.
You will have the opportunity to practice the EMER
ELEC CONFIG procedure during your simulator sessions.
We will now study the case of a RAT stall.
ELECTRICAL MENU
Abnormal operation (C) 35/54
If the RAT stalls, for example at low speed during
the approach, the emergency generator is no longer
powered and the supply is automatically transferred
to the batteries.
ELECTRICAL MENU
Abnormal operation (C) 36/54
The ECAM ELEC page has been called for you.
Observe that the EMER GEN indications have
disappeared.
ELECTRICAL MENU
Abnormal operation (C) 37/54
As the battery discharge current is high, the
current indications are displayed in amber.
ELECTRICAL MENU
Abnormal operation (C) 38/54
The batteries feed the DC ESS bus and, via the
static inverter, supply the AC ESS bus.
ELECTRICAL MENU
Abnormal operation (C) 39/54
Both SHED ESS buses are automatically shed
which is indicated by amber SHED indications
below their respective buses.
Notice that, during this phase, the APU start is
inhibited.
ELECTRICAL MENU
Abnormal operation (C) 40/54
On the ground, the DC BAT bus is automatically
connected to the batteries. At low speed, the AC
ESS bus is shed leading to the loss of all screens.
ELECTRICAL MENU
Abnormal operation (C) 41/54
We will now review some indications we did not
have the opportunity to see when performing the
previous procedures.
ELECTRICAL MENU
Abnormal operation (C) 42/54
As a result of the electrical failure, the RAT is
normally automatically deployed. During the RAT
extension, the electrical system is powered from the
batteries.
The approximate flight time on batteries is 30 min.
Let’s see what happens if the RAT fails to deploy
automatically.
ELECTRICAL MENU
Abnormal operation (C) 43/54
If the RAT fails to extend, a specific line
appears in the EMER ELEC procedure telling you
to manually extend the RAT on the EMER ELEC
PWR panel.
Prreessss tthheeMAN ON ppbb ssw..
ELECTRICAL MENU Abnormal operation (C) 44/54
Noo,, rraaiissee tthheeMAN ON gguuaarrdd..
If the RAT fails to extend, a specific line
appears in the EMER ELEC procedure telling you
to manually extend the RAT on the EMER ELEC
PWR panel.
ELECTRICAL MENU Abnormal operation (C) 45/54
Noo,, rraaiissee tthheeMAN ON gguuaarrdd..
If the RAT fails to extend, a specific line
appears in the EMER ELEC procedure telling you
to manually extend the RAT on the EMER ELEC
PWR panel.
ELECTRICAL MENU
Abnormal operation (C) 46/54
The guard is up. You now have to extend the
RAT.
Exxtteenndd tthhee RATT..
ELECTRICAL MENU Abnormal operation (C) 47/54
Noo,, pprreessss tthheeMAN ON ppbb ssw..
The guard is up. You now have to extend the
RAT.
ELECTRICAL MENU Abnormal operation (C) 48/54
Noo,, pprreessss tthheeMAN ON ppbb ssw..
The guard is up. You now have to extend the
RAT.
ELECTRICAL MENU
Abnormal operation (C) 49/54
After a RAT extension, if the
emergency generator is not
working, the red FAULT light
stays illuminated on the RAT &
EMER GEN indicator.
This failure causes the aircraft
to be powered only from the
batteries.
ELECTRICAL MENU
Abnormal operation (C) 50/54
In case of smoke detection
in the avionics bay, the amber
SMOKE light illuminates on the
GEN 1 LINE pb sw.
A Master caution and an
ECAM procedure are also
triggered.
ELECTRICAL MENU
Abnormal operation (C) 51/54
When the GEN 1 LINE pb sw is pressed
generator 1 is disconnected from the system.
Swiittcchh GEN 11 LLIINE OFFFF..
ELECTRICAL MENU Abnormal operation (C) 52/54
Noo,, pprreessss tthhee GEN 11 LLIINE ppbb ssw..
When the GEN 1 LINE pb sw is pressed
generator 1 is disconnected from the system.
ELECTRICAL MENU Abnormal operation (C) 53/54
Noo,, pprreessss tthhee GEN 11 LLIINE ppbb ssw..
When the GEN 1 LINE pb sw is pressed
generator 1 is disconnected from the system.
ELECTRICAL MENU Abnormal operation (C) 54/54
The avionics smoke ECAM procedure leads to
中国航空网 www.aero.cn