Right pitot ADM channel is faulted or
unpowered.
PSEU 1 ............................................... 320 011 01 PSEU 1 is not transmitting on A629.
PSEU 1 CHANNEL ....................................... 320 012 01 One A629 channel in PSEU 1 is inoperative.
PSEU 2 ............................................... 320 011 02 PSEU 2 is not transmitting on A629.
PSEU 2 CHANNEL ....................................... 320 012 02 PSEU 2 is not transmitting on one A629 channel.
EFFECTIVITY
.
EICAS STATUS MESSAGES
.
ALL PW .
Page 55 D633W113-BEJ Jan 05/04
R
MESSAGE/DESCRIPTION___________________ FAULT CODE
R GEAR DOOR SENSOR ................................... 326 031 42 Failure of one (but not both) right main landing gear door position sensor or disagreement of door sensors on same gear for more than 5 sec.
R GEAR UPLOCK SENSOR ................................. 326 021 42 Failure of one (but not both) uplock sensor on the right main landing gear or disagreement of uplock sensors on same gear for more than 5 sec.
RADIO ALT C .......................................... 343 051 43 The center radio altimeter output is lost, incaccurate, or intermittent.
RADIO ALT L .......................................... 343 051 41 The left radio altimeter output is lost, inaccurate, or intermittent.
RADIO ALT R .......................................... 343 051 42 The right radio altimeter output is lost, inaccurate, or intermittent.
.RAM AIR EXIT DOOR L .................................. 215 062 41 . Left RAM air exit door not in commanded positon . or loss of position feedback. . .RAM AIR EXIT DOOR R .................................. 215 062 42 . Right RAM air exit door not in commanded . position or loss of position feedback. .
RAM AIR INLET DOOR L ................................. 215 061 41 Left RAM air inlet door not in commanded position or loss of position feeback.
RAM AIR INLET DOOR R ................................. 215 061 42 Right RAM air inlet door not in commanded position or loss of position feedback.
EICAS STATUS MESSAGES
PW Page 56 D633W113-BEJ Jan 05/04
R
MESSAGE/DESCRIPTION___________________ FAULT CODE
RAT DEPLOY INOP ...................................... 292 011 00 RAT ground maintenance control valve not in "flight" mode.
RAT GEN HEAT ......................................... 292 021 00 RAT generator heater failed.
RECIRC FAN ........................................... 212 001 00 Failure of 1 or more cabin air recirculation fans.