 PACK L ............................................... 215 002 41 1) Overheat at left pack outlet or left pack compressor outlet OR 2) Left Pack Flow Control Valves (FCVs) are closed due to: FCVs failed closed, FCVs latched closed by Cabin Temp Controller (CTC) because of fault, overheat, or pack flow sensing failure, OR 3) Both FCVs failed in any position.
 PACK OUT TEMP SNSR L ................................. 215 053 41 Left pack outlet temperature sensor and left pack 2nd stage turbine inlet temperature sensor failed.
 PACK OUT TEMP SNSR R ................................. 215 053 42 Right pack outlet temperature sensor failed and right pack 2nd stage turbine inlet temperature sensor failed.
EFFECTIVITY
 .
EICAS STATUS MESSAGES
.
 ALL PW .
Page 53 D633W113-BEJ Jan 05/04
P
MESSAGE/DESCRIPTION___________________ FAULT CODE
 PACK R ............................................... 215 002 42 1) Overheat at right pack outlet or right pack compressor outlet, OR 2) Pack flow control valves are closed due to FCVS failed closed, FCVS latched closed by CTC because of fault, overheat, or pack flow sensing failure, OR 3)
 Both FCV's failed in any position.
 PASS OXYGEN C ........................................ 352 031 43 Circuit Breaker C35405 in ELMS panel P310 is tripped.
 PASS OXYGEN L ........................................ 352 031 41 Circuit Breaker C35403 in ELMS panel P310 is tripped.
 PASS OXYGEN R ........................................ 352 031 42 Circuit Breaker C35404 in ELMS panel P310 is tripped.
 PASSENGER ADDRESS .................................... 233 001 00 The selected passenger address (PA) system controller (primary or alternate) is failed or faulted. Or some other passenger address system failure exists.
 PDCU L ............................................... 239 021 41 Left Panel Data Concentrator Unit (PDCU) is faulted.
 PDCU R ............................................... 239 021 42 Right Panel Data Concentrator Unit (PDCU) is faulted.
 PFC CHANNEL .......................................... 270 014 00 One of Three Primary Flight Computers failed. All three lanes are operative in each of remaining two PFC's (3:3:0 configuration).
EFFECTIVITY
 .
EICAS STATUS MESSAGES
.
 ALL PW .
Page 54 D633W113-BEJ Jan 05/04
P
MESSAGE/DESCRIPTION___________________ FAULT CODE
 PFC CONTROL LANES .................................... 270 013 00 2 of 9 primary flight computer lanes failed.
 PFCS INTERFACE ....................................... 270 015 00

 One of the following PFCS interface failures
 has occurred: 1) 2 or more ACE's with analog
 flap discrete disagrees 2) Only 2 of 4 FSEU
 data channel are available, 3) Only 2 of 4 WES
 data channels are available.
 