EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. GUN 001-007 ú
26-23-01
ú ú 10 Page 602 ú Jun 20/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
C99269
A
757
MAINTENANCE MANUAL
TO FORWARD TO AFT BOTTLE NO. 1
(YELLOW) COMPARTMENT DISCHARGE LINE FORWARD (BLUE) COMPARTMENT BOTTLE NO. 2 ASEE TUBING COMPARTMENT TO FORWARD
PRESSURE SWITCH SEE B
BOTTLE NO. 2
FIRE BOTTLE NO. 1
EXTINGUISHER TUBING
SEE C
SEE C
FILTER/DRIER DISTRIBUTION NOZZLE
1
(EXAMPLE) AFT CARGO
FWD DOOR
AFT CARGO COMPARTMENT
HARD POINT HARD POINT
CONNECTOR CONNECTOR
REGULATOR
FILTER/DRIER 1
1
AFT CARGO COMPARTMENT
PUSHBUTTON PRESSURE OR HEX KEY SWITCH
THERMAL RELIEF AND REFILL
CARRYING HANDLES
SEE D
FLIGHT COMPARTMENT
ARMED ARMED
MOUNTING BRACKETS
FWD AFT
r r
C A R
DISCHARGE
G PORT O
1-BTL DISCH-2
F
I
R
E DISCHARGE
SQUIB
DISCH DISCH
aa
CARGO FIRE BOTTLE APU/CARGO FIRE CONTROL PANEL
C D
Cargo Compartment Fire Extinguishing System Figure 601 (Sheet 2)
C99271
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. GUN 008-999 ú
26-23-01
ú ú 09 Page 603 ú Jun 20/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
S 866-002
(2) Open these circuit breakers on the main power distribution panel, P6, and attach DO-NOT-CLOSE tags:
(a)
6H1, FIRE EXTINGUISHING ENG L BTL 1
(b)
6H5, FIRE EXTINGUISHING CARGO BTL 1
(c)
6H6, FIRE EXTINGUISHING CARGO BTL 2
S 866-172
(3) Open these circuit breakers on the overhead circuit breaker panel, P11, and attach DO-NOT-CLOSE tags:
(a)
11J2, INSTRUMENTS EICAS CMPTR LEFT
(b)
11J29, INSTRUMENTS EICAS CMPTR RIGHT
S 016-189
(4)
Gain access to the lower cargo fire extinguishing bottles. The bottles are located behind the liners located in the forward end of the aft cargo compartment.
S 426-003
(5)
On the lower cargo compartment fire extinguisher bottles 1 and 2, disconnect these connectors per Table 601:
Cargo Fire Bottle Connections Table 601:
_______________________________________
~................................................................. | Connector | Bottle Connected To: | ................................................................... | D4412 | Bottle 1 - Fwd Cargo discharge Squib | | | | | D4414 | Bottle 1 - Aft Cargo discharge Squib | | | | | D4418 | Bottle 2 - Fwd Cargo discharge Squib | | | | | D4420 | Bottle 2 - Aft Cargo discharge Squib | | | | 2..................…..............................................1
S 436-173
WARNING:_______PUT THE PROTECTIVE COVERS ON THE FIRE BOTTLE SQUIBS. IF YOU DO NOT PUT THE PROTECTIVE COVERS ON THE FIRE BOTTLE SQUIBS, THE FIRE BOTTLES CAN RELEASE ITS CONTENTS SUDDENLY AND CAUSE INJURY TO PERSONS.
CAUTION:_______DO NOT PUT SHUNT PLUGS ON THE FIRE BOTTLE SQUIBS. THE SHUNT PLUGS CAN CAUSE DAMAGE TO THE SQUIB PINS.
(6) Put the protective covers on all the fire bottle squibs.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-23-01
ALL ú ú 01 Page 604 ú May 28/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
S 436-183
(7)
Connect the multimeter to the squib test box.
S 436-184
(8)
Attach the adapter cable to the connector on the squib test box.
NOTE: Adapter cables are included with the squib test box and
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 防火 FIRE PROTECTION 2(90)