S 864-094
(2)
Make sure this circuit breaker on the P6 panel is closed:
(a) 6G1, FIRE EXT APU
S 984-016
(3)
Push the TEST switch on the SQUIB TEST control panel at the right side of the P61 panel.
S 214-019
(4)
Make sure that the green APU squib light on the SQUIB TEST control panel, P61, comes on.
S 214-020
(5)
Release the TEST switch.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-22-01
ALL ú ú 04 Page 408 ú Sep 28/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
S 214-079
(6)
Make sure the test light goes off.
S 464-023
(7)
Remove electrical power if it is not necessary (AMM 24-22-00/201).
TASK 26-22-01-024-100
4. Remove the APU Fire Extinguisher Bottle_______________________________________
A. Equipment
(1) Squib Protective Cover
M83723/60-18-AN or AC (Engine or APU)
M83723/60-110-AN or AC (Engine or APU)
(2) Discharge Port Cap - (Supplied with the fire extinguisher bottles).
B. References
(1)
AMM 06-42-00/201, Empennage (Major Zone 300) Access Doors and Panels
(2)
AMM 20-41-01/201, Electrostatic Discharge Sensitive Devices
(3)
AMM 24-22-00/201, Electrical Power - Control
C. Access
(1)
Location Zones
211 Flight Compartment (Left)
212 Flight Compartment (Right)
315 APU Compartment (Left)
316 APU Compartment (Right)
(2)
Access Panels
313AL Control Bay Access Door
315AL APU Access Door
316AR APU Access Door
D. Remove APU Fire Extinguisher Bottle (Fig. 401)
S 864-024
(1) Open this circuit breaker on the P6 panel and attach a DO-NOT-CLOSE tag:
(a) 6G1, FIRE EXT APU
S 944-026
WARNING: STAY OFF THE SERVICE ACCESS DOOR, 311AL, AND THE ACCESS DOOR
_______ FOR THE CONTROLS BAY, 313AL. YOUR WEIGHT CAN CAUSE THE SPRING-LOADED LATCHES TO RELEASE. IF YOU FALL THROUGH THE DOOR, INJURY CAN OCCUR.
(2) Open the controls bay access door, 313AL (AMM 06-42-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-22-01
ALL ú ú 04 Page 409 ú Sep 28/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
S 864-131
WARNING:_______ DO NOT TOUCH THE SQUIB BEFORE YOU DO THE PROCEDURES FOR DEVICES
THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC
DISCHARGE CAN CAUSE THE FIRE BOTTLE TO RELEASE ITS CONTENTS
SUDDENLY AND CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
(3)
Before you touch the squib, do the procedure for devices that are sensitive to electrostatic discharge (AMM 20-41-01/201).
S 034-027
(4)
Disconnect the electrical connectors (1,3) from the bottle squib and pressure switch. Refer to Table 401.