(b)
Make sure the R ENG 1, L ENG 2, and R ENG 2 squib test lights stay off.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-21-01
ALL ú ú 01 Page 415 ú Sep 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
S 214-056
(6) Release the TEST switch.
(a) Make sure the L ENG 1 squib test light goes off.
S 434-060
(7)
Do the Squib Electrical Connection procedure to connect the electrical connector, D2190, to the right squib of bottle 1.
S 864-061
(8)
Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P6 panel:
(a) 6H3, FIRE EXTINGUISHING ENG R BTL 1
S 984-063
(9) Push and hold the TEST switch on the SQUIB TEST Control Panel, P61.
(a)
Make sure the green L ENG 1 and R ENG 1 squib test lights on the SQUIB TEST Control Panel come on.
(b)
Make sure the L ENG 2 and R ENG 2 squib test lights stay off.
S 214-066
(10) Release the TEST switch.
(a) Make sure the L ENG 1 and R ENG 1 squib test lights go off.
S 864-069
(11) Remove the DO-NOT-CLOSE tags and close these circuit breakers on the P6 panel:
(a)
6H2, FIRE EXTINGUISHING ENG L BTL 2
(b)
6H4, FIRE EXTINGUISHING ENG R BTL 2
I. Connect the squib electrical connectors of fire extinguisher bottle 2, if applicable.
S 864-070
(1) Make sure these circuit breakers on the P6 panel are open:
(a)
6H1, FIRE EXTINGUISHING ENG L BTL 1
(b)
6H2, FIRE EXTINGUISHING ENG L BTL 2
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-21-01
ALL ú ú 01 Page 416 ú Sep 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
(c) (d) 6H3, FIRE EXTINGUISHING ENG R BTL 16H4, FIRE EXTINGUISHING ENG R BTL 2
(2) S 434-121Do the Squib Electrical Connection procedure to connect the electrical connector, D2268, to the left squib of bottle 2.
(3) S 864-072Supply electrical power (AMM 24-22-00/201).
(4) S 864-073Remove the DO-NOT-CLOSE tag and close these circuit breakers on the P6 panel: (a) 6H1, FIRE EXTINGUISHING ENG L BTL 1 (b) 6H2, FIRE EXTINGUISHING ENG L BTL 2
(5) S 984-074Push and hold the TEST switch on the SQUIB TEST Control Panel, P61. (a) Make sure the green L ENG 1 and L ENG 2 squib test lights on the SQUIB TEST Control Panel come on. (b) Make sure the R ENG 1, and R ENG 2 squib test lights stay off.
(6) S 214-078Release the TEST switch. (a) Make sure the L ENG 1 and L ENG 2 squib test lights go off.
(7) S 434-080Do the Squib Electrical Connection procedure to connect the electrical connector, D2266, to the right squib of bottle 2.
(8) S 864-081Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P6 panel: (a) 6H4, FIRE EXTINGUISHING ENG R BTL 2
(9) S 984-082Push and hold the TEST switch on the SQUIB TEST Control Panel, P61. (a) Make sure the green L ENG 1, L ENG 2, and R ENG 2 squib test lights on the SQUIB TEST Control Panel come on. (b) Make sure the R ENG 1 squib test light stays off.
S 214-086
(10) Release the TEST switch.
(a) Make sure the L ENG 1, L ENG 2, and R ENG 2 squib test lights go off.
S 864-088
(11) Remove the DO-NOT-CLOSE tags and close these circuit breakers on the P6 panel:
(a)
6H1, FIRE EXTINGUISHING ENG L BTL 1
(b)
6H3, FIRE EXTINGUISHING ENG R BTL 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-21-01
ALL ú ú 02 Page 417 ú May 28/02
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 防火 FIRE PROTECTION 2(25)