SCAVENGE FILTER PRESSURE FILL ~P INDICATOR ADAPTER
SCAVENGE
(ACTIVATED) FILTER OVERFLOW DRAIN
INTEGRATED DRIVE GENERATOR WITH VACUUM PRESSURE VALVE (REAR VIEW)
B
LIFTING
BOSS
ELECTRICAL TERMINAL
CONNECTOR "B" BLOCK
OIL OUT
SPLINE
ELECTRICAL CONNECTOR "A"
DISCONNECT 
RESET RING 
OIL IN 
CASE THERMAL  CASE DRAIN (OIL)  GOVERNOR 
RELIEF VALVE  ADJUSTMENT 
1  FWD 
LEFT SIDE  PRESSURE FILL (OIL)  CASE THERMAL RELIEF VALVE 

C  OVERFLOW  CASE 
DRAIN (OIL)  DRAIN  OIL LEVEL 
(OIL)  INDICATOR 
1  SEAL DRAIN LINE CONNECTS TO  RIGHT SIDE 
CASE THERMAL RELIEF VALVE 

Generator Drive System Component Location
Figure 1 (Sheet 3)

 G82067
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-11-00
 ALL  ú ú 01 Page 4 ú Sep 20/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
ELECTRICAL CONNECTOR "B"
OIL OUT
CHARGE PRESSURE TEST PORT
TERMINAL
BLOCK
GENERATOR TERMINAL COVER
SEE D
SEE C OIL INELECTRICAL CONNECTOR "A"
SCAVENGE FILTER PRESSURE FILL
~P INDICATOR
SCAVENGE  ADAPTER
(ACTIVATED) FILTER
OVERFLOW
DRAIN
INTEGRATED DRIVE GENERATOR WITH EXTERNAL ASPIRATOR CASE VENT SYSTEM (REAR VIEW)
B
LIFTING
BOSS
ELECTRICAL TERMINAL
CONNECTOR "B" BLOCK
OIL OUT
SPLINE
ELECTRICAL CONNECTOR "A"
DISCONNECT 
RESET RING 
OIL IN 
CASE THERMAL  CASE DRAIN (OIL)  GOVERNOR 
RELIEF VALVE  ADJUSTMENT 
1  FWD 
LEFT SIDE  PRESSURE FILL (OIL)  CASE THERMAL RELIEF VALVE 

C  OVERFLOW  CASE 
DRAIN (OIL)  DRAIN  OIL LEVEL 
(OIL)  INDICATOR 
1  SEAL DRAIN LINE CONNECTS TO  RIGHT SIDE 
CASE THERMAL RELIEF VALVE 

Generator Drive System Component Location
Figure 1 (Sheet 4)

 G81876
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-11-00
 ALL  ú ú 01 Page 5 ú Sep 20/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
ELECTRICAL CONNECTOR "B" CHARGE PRESSURE
OIL OUT TEST PORT
TERMINAL
BLOCK
GENERATOR TERMINAL COVER
SEE D
SEE C
OIL IN CONNECTOR "A" ELECTRICAL
SCAVENGE FILTER PRESSURE FILL ~P INDICATOR ADAPTER
SCAVENGE
(ACTIVATED)
FILTER  OVERFLOW DRAIN
INTEGRATED DRIVE GENERATOR WITH INTERNAL ASPIRATOR CASE VENT SYSTEM (REAR VIEW)
B
LIFTING
BOSS
ELECTRICAL TERMINAL
CONNECTOR "B" BLOCK
OIL OUT
SPLINE
ELECTRICAL CONNECTOR "A"
DISCONNECT 
RESET RING 
OIL IN 
CASE THERMAL  CASE DRAIN (OIL)  GOVERNOR 
RELIEF VALVE  ADJUSTMENT 
1  FWD 
LEFT SIDE  PRESSURE FILL (OIL)  CASE THERMAL RELIEF VALVE 

C  OVERFLOW  CASE 
DRAIN (OIL)  DRAIN  OIL LEVEL 
(OIL)  INDICATOR 
1  SEAL DRAIN LINE CONNECTS TO  RIGHT SIDE 
CASE THERMAL RELIEF VALVE 

Generator Drive System Component Location
Figure 1 (Sheet 5)

 G82183
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-11-00
 ALL  ú ú 01 Page 6 ú Sep 20/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 电源 ELECTRICAL POWER 1(7)