................................................................................ |Visible magnetic or |No oil discoloration, |1. Replace the IDG | |non-metallic particles |no signs of over-| (AMM 24-11-01/401). | |in the scavenge filter |heating or chemical | | |and the scavenge filter |contamination of the | | |is not breached. |oil is not suspected | | |(See NOTE for more | | | |scavenge filter data) | | | |*[1] | | |
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-11-01
ALL ú ú 02 Page 617 ú May 20/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
~.............................................................................. | SCAVENGE FILTER AND OIL CONDITION CHECK | ................................................................................ | SCAVENGE FILTER | | | | CONDITION | IDG OIL CONDITION | ACTION | ................................................................................
|Visible magnetic or |Oil discoloration, |1. Remove the IDG |
|non-metallic particles |Signs of overheating | (AMM 24-11-01/401). |
|in the scavenge filter |or chemical | |
|and the scavenge filter |contamination of the |2. Flush the IDG oil system |
|is not breached. |oil is suspected. | (AMM 12-13-03/301). |
|(See NOTE for more |(Hydraulic fluid and | |
|scavenge filter data) |water) |3. Replace the IDG |
|*[1] | | (AMM 24-11-01/401). |
................................................................................ |Visible magnetic or |Oil condition is not |1. Remove the IDG | |non-metallic particles |a factor | (AMM 24-11-01/401). | |in the scavenge filter | | | |and the scavenge filter | |2. Replace the IDG air/oil | |is breached. | | cooler (AMM 24-11-04/401).| |(See NOTE for more | | | |scavenge filter data) | |3. Replace the IDG oil cooler| |*[1] | | lines. | | | | | | | |4. Install a new IDG. | | | | (AMM 24-11-01/401). | ................................................................................ |*[1] NOTES: | |If the scavenge filter element or filter cover shows a number of moderately | |scattered, small metallic flakes (bronze or silver colored metal), flakes of | |generator insulation, black epoxy flakes, or sleeving, do not replace the IDG.| |These products are normal wear during IDG operation. | | | |If the filter element shows bright metal deposits that can be clearly | |specified as chunks or pieces caused by breakage, or a large number of small | |metallic flakes (bronze or silver colored metal), replace the IDG. These are | |indications of IDG internal damage. | | | |The filter is breached if the filter is damaged or missing, the O-ring is | |damaged or missing, or the filter cap is damaged or loose. | 2.........................…......................….............................1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-11-01
ALL ú ú 02 Page 618 ú May 20/98