Remove the circuit breaker lock(s).
S 862-013
WARNING: KEEP PERSONS AND EQUIPMENT CLEAR OF THE SYSTEM RELATED TO THE
_______ TRIPPED CIRCUIT BREAKER. MAKE SURE THAT THERE IS NO DAMAGE TO THE ELECTRICAL WIRING AND SYSTEM COMPONENTS. MAKE SURE THAT ALL TERMINAL CONNECTIONS ARE TIGHT. DAMAGED ELECTRICAL WIRING, DAMAGED SYSTEM COMPONENTS AND LOOSE TERMINAL CONNECTIONS CAN CAUSE ELECTRICAL ARCING AND A FIRE WHEN THE CIRCUIT BREAKER IS CLOSED.
IF THE TRIPPED CIRCUIT BREAKER IS RELATED TO THE FUEL SYSTEM, OBEY CHAPTER 28 OF THE AIRCAFT MAINTENANCE MANUAL AND THE FAULT ISOLATION MANUAL. THERE ARE PROCEDURES IN CHAPTER 28 THAT DO NOT ALLOW THE RESETTING OF TRIPPED CIRCUIT BREAKERS. ELECTRICAL ARCING CAN CAUSE IGNITION OF FUEL OR FUEL VAPORS AND THE RESULT CAN BE A FIRE OR EXPLOSION.
(12)
Close the circuit breaker(s).
S 862-014
(13)
After you close the circuit breaker(s), make sure that there is no electrical arcing or other damage to the system.
S 862-015
(14)
To make sure that the airplane system operates correctly, refer to the applicable procedure in the Aircraft Maintenance Manual (AMM).