• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-15 08:32来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

______________________________
 1. General
_______
 A. This procedure contains a task to do a check of the nose radome.
 B. To do a check of the nose radome you must do these steps:
 (1)  
Do a visual check of the radome for damage.

 (2)  
Do a check for moisture in the radome.

 (3)  
Do a visual check of the diverter strips for damage.

 (4)  
Do a check of the diverter strips for conductance.


 C. You must make sure the installation of the nose radome is correct.
 TASK 53-52-01-206-001
 2. Nose Radome - Inspection
________________________
 A. Standard Tools and Equipment
 (1)  
Meter - Bonding (Ref 20-22-01/601)

 (2)  
Detector - Moisture Register (Model: A8-AF) .
 Penta Engineering
 Moisture Register Products
 P.O.BOX 369
 La Verne CA 91750-0369
 Phone (714) 392-5833
 Fax (714) 392-5838

 

 B. References
 (1)  53-52-01/201, Nose Radome
 C. Access
 (1)  Location Zone
 111 Radome

 D. Procedure
 S 216-002
 (1)  Examine the nose radome for holes, scuffs, cracks, blisters, and delamination.
 NOTE: To find the delamination, lightly hit the radome skin with
____ a small metal object. For example, you can use a short socket handle.
 S 216-012
 (2) Look for signs of lightning strikes (Ref 05-51-13/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 53-52-01
 ALL  ú ú 01 Page 601 ú Oct 10/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 286-003
 (3)  Do a check for moisture.
 NOTE: The moisture register detector measures the
____ conductance of the radome material to find moisture. The register contains two major parts, the gun and the case. The gun contains the electrodes and the oscillator circuits. The case contains the ON-OFF switch, the meter control to adjust to zero, and the batteries.
 (a)  Adjust the meter until it shows zero:
 1)  Move the gun part of the moisture register detector to a minimum of 3 inches from an object.
 NOTE: An object near the gun will cause the zero
____ adjustment on the meter to change.
 2)  Push the ON-OFF button on the case of the moisture register detector to ON.
 NOTE: The moisture register detector must be on during the
____
 full check.

 a) Permit the moisture register detector to become stable. b) Use the adjustment knob on the left of the handle to adjust the needle to zero on the dial.
 (b)  Do a check of the radome: 1) Open the nose radome. 2) Move the gun of the moisture register detector until the
 gun electrodes touch the inner surface of the radome. 3) Make sure the eight electrodes touch the surface of the nose radome. 4) Move the gun along all the inner surface and make sure the meter stays in the GOOD (0-5) range. 5) Do a check again of the areas which cause the meter to read more than one.
 6)  If there is an indication of moisture (above 5 on the scale), remove moisture and seal in accordance with SRM 53-10-72
 S 216-004
 (4)  Make sure the attachment of the aluminum diverter strips is tight.
 NOTE: Sharp corners or points along a conductive strip can cause
____
 the radio transmission to not operate correctly.

 S 216-006
 (5)  Do a check for burned areas and corrosion.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 53-52-01
 ALL  ú ú 01 Page 602 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 416-007
 (6)  
Close the nose radome.

 S 766-014

 (7)  
Measure the resistance between the diverter strips and the body structure skin.


 (a)  Maximum reading should be 0.01 Ohms although in-service values up to 0.1 Ohms are common.
 NOTE: Resistances above 0.01 Ohms can indicate potential
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 机身 FUSELAGE(52)