C. Procedure
S 862-046
(1) Show page 2 of the CMC MENU on the CDU:
(a)
Push the MENU key on the CDU to show the CDU MENU.
(b)
Push the <CMC LSK (line select key) to show the CMC MENU.
(c)
If the CMC MENU is not shown after you push the CMC LSK, push the <RETURN LSK until you see the CMC MENU.
(d)
Push the NEXT PAGE key to show page 2 of the CMC MENU.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
45-10-00
ALL ú ú 06 Page 235 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE/CMCS BITE MANUAL
WORD LABEL, AND SDI INTO THE SCRATCHPADCDU SCRATCHPAD
Input Monitoring Figure 209 (Sheet 1)
C20787
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
45-10-00
ALL ú
ú 08 Page 236
ú Oct 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE/CMCS BITE MANUAL
1L -/
2L
3L
4L
5L <FREEZE
6L <RETURN E/42/160/00
INPUT MONITORING PAGE
"SAMPLE" IS SHOWN WHEN
INPUT MONITORING 1/8 PORT LBL SDI 1L E/42/160/00 ENGR > 1R SAMPLE BIN 2L 0011000000000000 BIN> 2R 0010000000 101001 3L 1100000000 000 000 HEX> 3R 0000 00000101001 4L 0110 00000 000 000 4R
5L 5R
6L 6R
CDU KEY
THE CMC GETS A NEW DATA SAMPLE. "SAMPLE" CAN FLASH
NEWEST DATA SAMPLE
PREVIOUS DATA SAMPLE
OLDEST DATA SAMPLE
BIT 32
BIT 16
PUSH THE "<FREEZE" LSK TO HOLD THE VALUES DISPLAYED. PUSH THE SAME LSK TO SEE NEW DATA SAMPLES AGAIN.
0 0 0000 000000101001-------<FREEZE REPORT>
<RETURN HELP>
PREV NEXT PAGE PAGE
INPUT M0NITORING 2/8 PORT LBL SDI E/46/160/00
BIN 011000000000 1000 BIN> 0001000000011001 0010000000000 000 HEX> 1000000100011001 0001010000000 000 0000000 000011001-------
<FREEZE REPORT>
<RETURN HELP>
Input Monitoring Figure 209 (Sheet 2)
NON P U T S DL B LP O R T -----/---/ MI I T O R I I GN 1/ 8
A F I E L DT AD 1 B I N B I N >
D A F I E L DT A 2 H E X >
D F I E L DA T A 3
R E P O R T>
HELP>
IF "ENGR>" IS SHOWN, PUSH THE LSK TO SEE THE DATA IN ENGINEERING UNITS
TO SEE THE DATA IN
BINARY NUMBERS, PUSH
THE "BIN>" LSK
TO SEE THE DATA IN IN HEXIDECIMAL NUMBERS, PUSH THE "HEX>" LSK
FIRST INPUT MONITORING PAGE
PUSH THE "NEXT PAGE"
OR "PREV PAGE" KEY
TO MONITOR A DIFFERENT
SDI, WORD, OR PORT.
BIT 17
1R
BIT 1
4R
6R
SECOND INPUT MONITORING PAGE
1L 2L 2R 3L 3R 4L 5L 5R 6L
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
45-10-00
ALL ú ú 07 Page 237 ú Oct 10/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE/CMCS BITE MANUAL
S 862-047
(2) Do input monitoring on one location:
(a)
Push the <INPUT MONITORING LSK to show an empty INPUT MONITORING page on the CDU.
(b)
Use the CDU keyboard to put the port location, port number, word label, and SDI into the CDU scratchpad area.
NOTE: It is not necessary to include initial zeros in the
____ port number or the word label.
(c)
Push the top left LSK to replace the adjacent symbols (-/---/---/---) with the location you put into the CDU scratchpad.
(d)
Set the type of input monitoring display: 1) To see the data in binary numbers, push the LSK adjacent to the BIN> prompt. 2) To see the data in hexidecimal numbers, push the LSK adjacent to the HEX> prompt.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 中央维护计算机系统(41)