(b)
Also on the OTHER FUNCTIONS menu are these prompts which are used to enable or inhibit a flight leg transition: ENABLE FLT LEG ROLL and INHIBIT FLT LEG ROLL. Only one prompt shows at a time. Selection of one prompt causes the other prompt to show. 1) Selection of INHIBIT FLT LEG ROLL makes sure the flight leg
does not change.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
45-10-00
ALL ú ú 09 Page 21 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
2) Selection of ENABLE FLT LEG ROLL allows the flight leg to change the next time the first engine is started (or, if the engines are running, when the last door is closed). Selection of ENABLE FLT LEG ROLL is the same to the CMC as the engines reaching take-off thrust with the parking brake released.
3) Selection of INHIBIT FLT LEG ROLL or ENABLE FLT LEG ROLL must be for only one CMC. The command is automatically sent to the other CMC so that the flight leg numbers stay the same in the two CMCs.
(14) Shop Faults (Fig. 16)
(a)
The shop faults function supplies shop relevant fault (SRF) data for a selected LRU. The CMCS transmits a signal to an LRU to cause the LRU to transmit SRF data to the CMC. The SRF data is shown on a CDU.
(b)
SHOP FAULTS page
1) The SHOP FAULTS page shows a list of all systems that have LRUs with SRF data. The list is in ATA chapter sequence.
(c)
SHOP FAULTS LRUS page
1) The SHOP FAULTS LRUS page shows the LRUs in the selected system that have available SRF data.
(d)
SHOP FAULTS DATA page
1) The SHOP FAULTS DATA page shows SRF data that the LRU transmits to the CMC.
(15) Input Monitoring (Fig. 17)
(a)
The input monitoring function permits monitoring of inputs to the CMCs or the EIUs. Eight different inputs to the EIUs can be monitored at the same time. Only one input to the CMC can be monitored at a time.
(b)
INPUT MONITORING pages 1) The INPUT MONITORING page is first shown without data. The CDU keyboard is used to select the location to monitor.
2) The page then shows three data samples. The newest sample is shown above the other two samples. A new data sample is shown each 0.5 seconds.
3) Selection of the <FREEZE prompt stops the display of new data samples. Selection of the <RESUME prompt starts the display of new samples.
4) The data can be shown in binary or hexadecimal numbers. Some data can also be shown in decimal numbers. 5) Eight pages can be shown. Each page shows data from a different input.