AC GENERATOR DRIVE SYSTEM - TROUBLE SHOOTING
1. General
A. Trouble shooting charts on the following pages are set up to aid in locating causes of specific symptoms that may appear in starting and operating the ac generator constant speed drive system. The charts are arranged so that by starting at the top and proceeding downward the trouble may be isolated and corrected. Such trouble charts can not be given for every possible trouble that may occur, but may be used as a guide in isolating troubles not listed.
CAUTION: BEFORE RECONNECTING A DISCONNECTED CSD TO PERFORM TROUBLE SHOOTING, CHECK CSD OIL FILTER PRESSURE DIFFERENTIAL INDICATORS, CSD OIL LEVEL AND CONDITION, AND CSD MAGNETIC PLUG PER 24-11-11, I/C. RECONNECTING A CSD WITH FAULTS IN THESE AREAS MAY RESULT IN SEVERE DAMAGE TO THE CSD.
2. Trouble Charts
500
Feb 20/85 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 24-11-0 Page 101
H29114 H29107 H29098 H29090 H29088 H29085
500
24-11-0 Page 102 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. Nov 15/67
500
Nov 15/79 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 24-11-0 Page 103
500
24-11-0 Page 104 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. Nov 15/79
500
May 15/70 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 24-11-0 Page 105
500
24-11-0 Page 106 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. Nov 15/79
500
May 15/70 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 24-11-0 Page 107
AC GENERATOR DRIVE SYSTEM - MAINTENANCE PRACTICES
1. General
A. This section provides a procedure for pressurizing the CSD hydraulic system to check for oil leaks with the engines shut down.
2. Equipment and Materials
A. CSD leak tester (Fig. 201), consisting of the following:
(1)
Hose adapter OMP 2506-3, Ozone Metal Products, 101-32 101st St., Ozone Park, Long Island, N.Y.
(2)
Flexible hose (approximately 6 feet in length), capable of withstanding 100 psi
(3)
Relief valve, pre-set at 50 psi
(4)
Regulator with 0 to 100 psi pressure gauge
(5)
Relief valve, pre-set at 100 psi
(6)
Shut-off valve
(7)
Fittings, as required
B. Dry compressed air source, or a regulated nitrogen source (100 psi maximum).
3. Check CSD Hydraulic System For Leaks
A. Position the shut-off valve to OFF and shut off the regulator valve to prevent pressurization of CSD.
B. Connect hose adapter to CSD pressure fill fitting.
C. Connect the other end of tester to the compressed air or regulated nitrogen source.
D. Turn the shut-off valve to ON and adjust the regulator to 25 PSIG.
CAUTION: DO NOT EXCEED 50 PSIG TO THE CSD. DAMAGE TO CSD MAY RESULT.