BOMB INDICATION LINE.........................................................................................POSITION
Note: A bomb location indicator line is a 6 to 8 ft (1.8 to 2.4 m) (e.g. neckties, headset
cord, or belts connected together) preferably of constrating color, that helps the
responding bomb squad find the precise location of the suspect device within the
LRBL stack once constructed.
Position the bomb indication line from the location on the platform where you will place the
suspect device, EXTENDING outward into the aisle.
BOMB..............................................................................................................MOVE TO LRBL
Carefully carry in the attitude found and place on top of the wetted materials in the same
attitude and as close to the door structure as possible.
CAUTION Ensure that the suspect device, when placed on the stack against the door,
is above the slide pack but not against the door handle, and if possible, avoid
placement in the view port.
LEAST RISK BOMB LOCATION (LRBL)...............................................................COMPLETE
Place an additional single thin sheet of plastic over the bomb.
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
MISCELLANEOUS
A318/A319/A320/A321 FLEET PRO-ABN-80 P 53/182
FCOM 19 AUG 10
BOMB ON BOARD (Cont'd)
CAUTION DO NOT OMIT THE PLASTIC SHEETS, AS THE SUSPECT DEVICE
COULD GET WET AND POSSIBLY SHORT CIRCUIT ELECTRONIC
COMPONENTS CAUSING INADVERTENT DEVICE ACTIVATION.
Build up at 25 cm (10 in) of wetted material around the sides and on top of the bomb.
DO NOT PLACE ANYTHING BETWEEN THE BOMB AND THE DOOR, AND MINIMIZE
AIRSPACE AROUND THE BOMB.
The idea is to build up a protective surrounding of the bomb so that the explosive force is
directed in the only unprotected area into the door structure.
Fill the area around the bomb with seat cushions and other soft materials such as hand
luggage (saturated with water or any other nonflammable liquid) up to the cabin ceiling,
compressing as much as possible. Secure the LRBL stack in place using belt, ties or other
appropriate materials. The more material stacked around the bomb, the less the damage will
be.
USE ONLY SOFT MATERIAL. AVOID USING MATERIALS CONTAINING ANY
INFLAMMABLE LIQUID AND ANY METAL OBJECTS WHICH COULD BECOME
DANGEROUS PROJECTILES.
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
MISCELLANEOUS
A318/A319/A320/A321 FLEET PRO-ABN-80 P 54/182
FCOM 19 AUG 10
BOMB ON BOARD (Cont'd)
LRBL STACK
PASSENGERS.................................................................................................. MOVE/ADVISE
Move passengers at least 4 seat rows away from the least risk bomb location (RH aft cabin
door). On full flights, it may be necessary to double up passengers to achieve standoff from
the suspect device.
Passengers near the bomb should protect their heads with pillows, blankets. All passengers
must remain seated with seatbelts on and, if possible, head below the top of the head rest.
Seat backs and tray tables must be in their full upright position.
CABIN CREW........................................................................................ NOTIFY COCKPIT CREW
Cabin crew notify the flight crew that the bomb is secured at the LRBL.
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
MISCELLANEOUS
A318/A319/A320/A321 FLEET PRO-ABN-80 P 55/182
FCOM 19 AUG 10
BOMB ON BOARD (Cont'd)
EVACUATION/DISEMBARKATION.................................................................................EXECUTE
Evacuate through normal and emergency exits on the opposite side of the “bomb” location. Do
not use the door just opposite the “bomb”.
Use all available airport facilities to disembark without delay.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
MISCELLANEOUS
A318/A319/A320/A321 FLEET PRO-ABN-80 P 56/182
FCOM 19 AUG 10
BOMB ON BOARD
Applicable to:
IF POSSIBLE, LAND AND EVACUATE THE AIRCRAFT IMMEDIATELY.
If it is not possible to land and evacuate the aircraft within 30 min, apply the following procedures:
COCKPIT PROCEDURES
BACKGROUND
To avoid the activation of an altitude-sensitive bomb, the cabin altitude should not exceed the
value at which the bomb has been discovered.
To reduce the effects of the explosion, the aircraft should fly as long as possible with
 
中国航空网 www.aero.cn