AIRCRAFT SYSTEMS
PNEUMATIC
ELECTRICAL SUPPLY
Intentionally left blank
A318/A319/A320/A321 FLEET DSC-36-40 P 2/2
FCOM 19 AUG 10
AIRCRAFT SYSTEMS
WATER / WASTE
Intentionally left blank
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
AIRCRAFT SYSTEMS
WATER / WASTE
PRELIMINARY PAGES - TABLE OF CONTENTS
A318/A319/A320/A321 FLEET DSC-38-PLP-TOC P 1/2
FCOM 19 AUG 10
DSC-38-PLP PRELIMINARY PAGES
TABLE OF CONTENTS......................................................................................................................................1/2
DSC-38-10 DESCRIPTION
GENERAL..........................................................................................................................................................1/10
POTABLE WATER............................................................................................................................................1/10
WASTEWATER SYSTEM.................................................................................................................................4/10
TOILET SYSTEM..............................................................................................................................................5/10
DSC-38-20 ELECTRICAL SUPPLY
BUS EQUIPMENT LIST......................................................................................................................................1/2
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
AIRCRAFT SYSTEMS
WATER / WASTE
PRELIMINARY PAGES - TABLE OF CONTENTS
Intentionally left blank
A318/A319/A320/A321 FLEET DSC-38-PLP-TOC P 2/2
FCOM 19 AUG 10
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
AIRCRAFT SYSTEMS
WATER / WASTE
DESCRIPTION
A318/A319/A320/A321 FLEET DSC-38-10 P 1/10
FCOM 19 AUG 10
GENERAL
Applicable to: ALL
The water and waste system :
distributes potable ‐ water to the toilets and the galleys.
‐ disposes waste water.
‐ stores toilet wastes.
The system is insulated to prevent water leaks and ice build up.
The water and waste control panel is on the forward cabin attendant’s panel.
POTABLE WATER
Applicable to: ,
, MSN,,
Potable water is stored in a 200 l tank (135 l  ) in the left hand side wall behind the aft cargo
compartment.
While airborne, the aircraft uses bleed air to pressurize the water system ; on ground, it uses air from
the service panel pressure port.
Potable water is piped to the galleys and lavatories. Manual shut-off valves isolate the forward mid
 and aft washbasins from the water system. These valves, easily identifiable by OPEN and SHUT
legends, are under washbasins or toilet bowls.
The system can be filled or drained from the service panel under the fuselage. Indicators on the
forward attendant’s panel and the aft service panel show how much water is in the water tank.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
AIRCRAFT SYSTEMS
WATER / WASTE
DESCRIPTION
A318/A319/A320/A321 FLEET DSC-38-10 P 2/10
FCOM 19 AUG 10
POTABLE WATER
Applicable to:
Potable water is stored in a 200 l tank in front of the wing box behind the forward cargo compartment.
While airborne, the aircraft uses bleed air to pressurize the water system ; on ground, it uses air from
the service panel pressure port.
Potable water is piped to the galleys and lavatories. Manual shut-off valves isolate the forward mid
 and aft washbasins from the water system. These valves, easily identifiable by OPEN and SHUT
legends, are under washbasins or toilet bowls.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
AIRCRAFT SYSTEMS
WATER / WASTE
DESCRIPTION
A318/A319/A320/A321 FLEET DSC-38-10 P 3/10
FCOM 19 AUG 10
The system can be filled or drained from the service panel under the fuselage. Indicators on the
forward attendant’s panel and the aft service panel show how much water is in the water tank.
POTABLE WATER
Applicable to:
MSN,
Potable water is stored in a 200 l tank in front of the wing box behind the forward cargo compartment.
While airborne, the aircraft uses bleed air to pressurize the water system ; on ground, it uses air from
the service panel pressure port.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
AIRCRAFT SYSTEMS
WATER / WASTE
DESCRIPTION
A318/A319/A320/A321 FLEET DSC-38-10 P 4/10
FCOM 19 AUG 10
Potable water is piped to the galleys and lavatories. Manual shut-off valves isolate the forward mid
 and aft washbasins from the water system. These valves, easily identifiable by OPEN and SHUT
legends, are under washbasins or toilet bowls.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320机组操作手册FLIGHT CREW OPERATING MANUAL 4(69)