(~ Pack by pass valve position
Indication is green.
C = Cold - Valve closed
H = Hot - Valve open.
(~ Pack compressor outlet temperature
ndication is green - Becomes amber if temperature above 230~C
CCM ALL
┏━━━━━━━━━━━━━━━━┳━━━━━━━━━━━━━━━┳━━━━━━━━━━━┓
┃ ┃ ┃1.21.10 P 14 ┃
┃ ┃ ┣━━━━━┳━━━━━┫
┃I -~ A318 ┃I AIR CAIR/CONDITIONING ┃SEQ 001 1 ┃ REV 23 ┃
┃ .,,,.8, ,, ~L,~ A319 ┃ ┃ ┃ ┃
┃ Lii,~ A320 ┃ ┃ ┃ ┃
┃ A~7-~'M" A321 ┃ ┃ ┃ ┃
┃ FLIGHT CREW OPERATING MANUAL ┃ ┃ ┃ ┃
┗━━━━━━━━━━━━━━━━┻━━━━━━━━━━━━━━━┻━━━━━┻━━━━━┛
~
~
Pack flow
ndication is normally green. Becomes amber if pack flow control valve is closed
Note : The pack flow indication can be up to 30 % below the actual flow rate
Pack flow control valve
@Green
@Ambe
@Green
@Ambe
not closed.
not closed, disagree with control position.
fully closed.
fully closed, disagree with control position
ECAM COND PAGE
@
~
Zone controller fault indication
ALTN MODE ~ Primary zone controller fault (green).
PACK BEG ~ Zone controller fault (basic regulation by packs only) (green)
No indication ~ Zone controller normal operation.
Cabin FAN fault indication
Appears amber if fault detected
CCM ALL
┏━━━━━━━━━━━━━━━━┳━━━━━━━━━━┳━━━━━━━━━┓
┃I -~ A318 ┃AIR COND/PRESS/VENT ┃1.21.10 P 15 ┃
┃ .*,,.8, ,, ~L,~ A319 ┃ ┃ ┃
┃ Lii,~ A320 ┃ ┃ ┃
┃ ┃ ┣━━━━┳━━━━┫
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
AIRBUS A320 Flight Crew Operating Manual1(98)