6-76 For Training Purposes Only
Sept 04
P I LOT T R A I N I N G GU I D E
ELECTRICAL
CNTL KEY
CNTL Key is used to display system control options.
NOTE
STALL WARN ADVANCE is either NORM or ADVANCE, see
Chapter 10 for more information.
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
SWITCH CONTROL 1/3
SLAT/FLAP RESET
STALL WARN ADVANCE
LEFT FOOTWARMER
RIGHT FOOTWARMER
HUMIDIFIER
OFF
NORM
ON
ON
AUTO
SWITCH CONTROL 2/3
AC 1 CABIN PWR
AC 2 CABIN PWR
AC 3 CABIN PWR
AC 4 CABIN PWR
ON
ON
ON
ON
GX_06_076
SWITCH CONTROL 3/3
DC 1 CABIN PWR
DC 2 CABIN PWR 1
DC 2 CABIN PWR 2
DC 2 CABIN PWR 3
ON
ON
ON
ON
STBY
For Training Purposes Only
Sept 04
6-77
P I LOT T R A I N I N G GU I D E
ELECTRICAL
TEST KEY
TEST Key is used to display and initiate test options. When TEST key is selected,
FIRE TEST is automatically highlighted. The TEST function can only be initiated by
selecting the associated key. After a TEST is complete, the next selection will
automatically be highlighted. To terminate a TEST, reselect appropriate key.
NOTE
Individual selection not covered.
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
GX_06_077
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
OFF
STBY
M
TEST CONTROL 2/2
RAT TEST OFF
6-78 For Training Purposes Only
Sept 04
P I LOT T R A I N I N G GU I D E
ELECTRICAL
FIRE TEST
FIRE TEST:
(Duration approximately 15 seconds)
Press the FIRE TEST activation button and note the following:
• Fire aural warning is activated
• Master warning lights flash
• Fire DISCH handles lights illuminate
• L and R ENG FIRE warning message comes on
• APU FIRE warning message comes on
• MLG BAY OVHT warning message comes on
• SMOKE warning messages come on as per completion smoke detectors item
• When the FIRE TEST is complete, all warning messages will go out, fire aural
warning deactivated, master warning lights go out and Fire DISC handles lights go
out
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
GX_06_078
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
TEST
OFF
OFF
OFF
OFF
OFF
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
GX_06_079
TEST CONTROL 1/2
FIRE TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
STALL TEST
OFF
OFF
OFF
OFF
OFF
OFF
AFTER 10 SECONDS
For Training Purposes Only
Sept 04
6-79
P I LOT T R A I N I N G GU I D E
ELECTRICAL
STALL TEST
STALL TEST
(Duration approximately 20 seconds)
Press the STALL TEST activation button and note the following:
• Stick shaker No. 1 activates, followed by stick shaker No. 2. Stall annunciated on
PFD
• Both shakers are activated, stall aural warning is activated, both stalls are
annunciated on both PFDs and IGN icon is present on EICAS
• Stick pusher is activated and both control columns move full forward and return to
neutral twice
NOTE
For more information, refer to Chapter 10, FLIGHT CONTROLS.
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
GX_06_080
TEST CONTROL 1/2
FIRE TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2