曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
automatically displayed) and can be acknowledged and reset via the Electrical
Management System (EMS). EMS Control Display Units (CDU) are installed on the
pilot’s and copilot’s side panel.
M
M
STANDBY
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
LINE SELECT Keys
Used to select
displayed items.
Page Title
Displayed when a
selection has been
made using page
select key.
Page Number
Displays which page is
selected and how many pages
are available.
Activation Keys
Used to switch
current status and
select display items.
STATUS Key
Displays the status
of tripped, out and
locked circuit
breakers. System Key
Displays circuit
breaker status by
aircraft system.
BUS Key
Displays circuit
breaker status by
electrical buses.
PREVIOUS PAGE
Key
Scrolls list to
previous page.
NEXT PAGE key
Scrolls list to next
page.
TEST Key
Displays system's
test options.
CNTL Key
Displays system's
control options. EMER CONT
Key
Displays bus
isolation status.
NOTE:
If no action is taken within 45
to 60 secs of page activation or
selection, the display will revert
back to STBY page.
GX_06_008
BRIGHTNESS
Control
CIRCUIT BREAKER - SYSTEM
DOORS
AIR COND/PRESS ELEC
AFCS
ENGINE
FIRE
FLT CONTROLS
APU
BLEED
CAIMS
COMM FUEL
1/2
6-10 For Training Purposes Only
Sept 04
P I LOT T R A I N I N G GU I D E
ELECTRICAL
The circuit breaker STATUS page will automatically appear, anytime a circuit breaker
trips, if the screen is blank and has been blank for 2 seconds, (CB TRIP message
appears on EICAS) or can be selected using STAT page select key.
M
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
FUEL COMPUTR CH B
DU 1
RAD ALT 1
AC1
AC ESS
DC ESS
DC ESS
DC 1
LOCKED
OUT
OUT
LOCKED
TRIP
ACPC
CCBP
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
FUEL COMPUTR CH B
DU 1
RAD ALT 1
AC1
AC ESS
DC ESS
DC ESS
DC 1
LOCKED
OUT
OUT
LOCKED
TRIP
ACPC
CCBP
GX_06_009
FUEL COMP B
Circuit breaker
identification
DC 1
BUS location of
affected circuit
breaker.
ACPC
Thermal circuit breaker
located on the component within
ACPC.
LOCKED
Circuit breaker has
been locked by
maintenance personnel.
OUT
Circuit breaker has
been selected out.
TRIP
Circuit breaker
has tripped.
CCBP
Thermal circuit breaker
located on Cockpit Circuit
Breaker Panel.
NOTE: Thermal circuit breakers cannot be reset via the EMS CDU.
For Training Purposes Only
Sept 04
6-11
P I LOT T R A I N I N G GU I D E
ELECTRICAL
Circuit breakers can be acknowledged, or acknowledged and reset, using the line
select keys.
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
FUEL COMPUTR CH B
DU 1
RAD ALT 1
STAB TRIM 2
AC1
DC ESS
DC ESS
DC 1
AC ESS
LOCKED
IN
LOCKED
TRIP
OUT
ACPC
CCBP
THERM CB CAN’T BE CHANGED FROM CDU
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
DU 1
RAD ALT 1
FUEL COMPUTR CH B
AC1
AC ESS
DC ESS
DC 1
DC ESS
LOCKED
OUT
LOCKED
TRIP
OUT
ACPC
CCBP
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUS
PREV
PAGE
NEXT
PAGE
CNTL TEST
BUS
EMER
CONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
DU 1
RAD ALT 1
FUEL COMPUTR CH B
AC1
AC ESS
DC ESS
DC 1
DC ESS
LOCKED
OUT
LOCKED
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
庞巴迪挑战者手册5(21)