The flow control system regulates airflow from the pneumatic duct to the air conditioning units.
The ACUs decrease the temperature and moisture content of the bleed air from the pneumatic
system. The ACUs are located in the aft equipment bay.
An alternate supply of fresh air is available via the ram air system.
Conditioned air is routed from the cooling packs to the mix manifold (distribution system).
The Avionics and Cockpit Display Exhaust system ensures the ventilation of the avionic equipment
and cockpit displays to prevent excessive heating.
The auxiliary pressurization system provides an alternate pressurization source for the cabin, in the
event of loss of both cooling packs.
GF0210_016
LEFT
FLOW
CONTROL
SYSTEM
LEFT
AIR CONDITIONING
SYSTEM
DISTRIBUTION
SYSTEM
RAM
AIR
PNEUMATIC
SYSTEM
VENTILATION
SYSTEM
RIGHT
AIR CONDITIONING
SYSTEM
RIGHT
FLOW
CONTROL
SYSTEM
AFT PASSENGER
COMPARTMENT
FLIGHT
COMPARTMENT
FORWARD
PASSENGER
COMPARTMENT
FORWARD
OUTFLOW
VALVE
AFT
OUTFLOW
VALVE
TEMPERATURE
CONTROL
SYSTEM
AIR CONDITIONING AND PRESSURIZATION
REV 51, Aug 14, 2006 Flight Crew Operating Manual
CSP 700−6
Volume 2
02−10−15
AIR CONDITIONING SYSTEM (CONT'D)
The AIR CONDITIONING synoptic is selected using the EICAS Control Panel, located on the
pedestal.
Mix Manifold
Pack Discharge
Temperature
Ram Air
Valve (RAV)
Air Conditioning
Pack
Trim Air
Valve
Compartment Temperature
Duct Supply
Temperature
Hot Air Shut−Off
Valve (HASOV)
Flow Control
Valve (FCV)
Selected Temperature
PACK Flow
Output
GF0210_017
EICAS Control Panel
AIR CONDITIONING
BLEED BLEED
RAM AIR
19°C 21°C 22°C
CKPT FWD AFT
20 °C 20 °C 23 °C
23 °C 23 °C 23 °C
L PACK
TRIM AIR
15°C
R PACK
12°C
LOW
EICAS
SCROLL SYSTEM SELECT
AIR CONDITIONING AND PRESSURIZATION
Flight Crew Operating Manual REV 41, Jul 08, 2004
CSP 700−6
Volume 2
02−10−16
AIR CONDITIONING SYSTEM (CONT'D)
Air Conditioning Packages (PACKS)
The cooling packs decrease the temperature and moisture content of the bleed air from the
pneumatic system. The packs are located in the aft equipment bay.
RAM AIR INLET
SCOOP
RAM AIR
OUTLETS
PACK DISCHARGE
DUCT
RAM AIR
VALVE
MIX
MANIFOLD
AFT PRESSURE BULHEAD REFERENCE
RECIRCULATION FAN (LH)
RIGHT PACK
LEFT PACK PACK
GF0210_018
The air conditioning package is composed of two cooling packs which decrease the temperature
and moisture content in the bleed air and deliver conditioned air to the mix manifold.
The RAM AIR system has two main functions:
• To supply air to the cooling packs’ heat exchangers.
• To cool the bleed air flow, (alternate air supply source in the event of a dual pack failure)
and is designed for use inflight, at altitudes below 15,000 feet.
AIR CONDITIONING AND PRESSURIZATION
REV 41, Jul 08, 2004 Flight Crew Operating Manual
CSP 700−6
Volume 2
02−10−17
AIR CONDITIONING SYSTEM (CONT'D)
Cooling Packs
The cooling packs function as follows:
• Bleed air flows through the FCV into the primary heat exchanger, where it is cooled by ram
air.
• From the primary heat exchanger, the air flows into the compressor of the air cycle machine,
where the temperature and pressure are increased.
• From the compressor, the air enters the main heat exchanger, where the temperature is
decreased again.
• From the main heat exchanger, the air passes into the high pressure water extraction loop
(Reheater/Condenser, Water Extractor), where much of the water is removed and
temperature is further decreased. The water is evacuated into the ram air cooling flow at the
inlet of the heat exchangers to increase cooling efficiency by evaporation.
• From the water extraction loop, the air enters the turbine of the air cycle machine, where the
temperature and pressure are decreased.
• From the turbine, the air flows back through the condenser, where the temperature is
increased slightly and is ducted to the mix manifold.
PRIMARY HEAT
EXCHANGER
WATER
SPRAYER
CONDENSER
TO MIXING
MANIFOLD
PDPS AFT PRESSURE BULKHEAD PDPS
 