respectively, left main, center auxiliary and right main fuel quantity. The tail tank
readout is on the last line. Fuel quantity and fuel flow are normally displayed in LB
(pounds) but can also be configured in KG (kilogram) at the Completion Center.
Fuel quantity data can also be read on the optional interior refuel panel (behind the
copilot seat).
Total fuel quantity data must be entered in the FMS (PERF INIT
page) prior to flight.
Bulk Fuel Temperature Indication
Temperature is monitored by a probe in the left main tank and displayed on the EICAS
status page. Numerals are green at temperatures above -37°C. At or below -37°C, the
numerals are amber and an associated BULK FUEL TEMP caution EICAS message
will be displayed.
Engine Fuel Temperature Indications
Temperatures are sensed by a probe located on the top of each engine’s fuel filter
housing. Numerals are green above 5°C and amber if below 5°C. An associated L/R
FUEL LO TEMP caution EICAS message will be displayed.
Fuel Flow Indications
Fuel flow indications are displayed for each engine immediately below the N2 arcs on
the primary EICAS page. The normally green fuel flow indication will turn amber and
display dashed lines if fuel flow exceeds 5000 pph, (2,273 kg/hr) or if the input value
is invalid. Fuel flow can also be viewed through FMS page selection.
NOTE
FUEL SYSTEM
For Training Purposes Only
Sept 04
12-31
P I LOT T R A I N I N G GU I D E
EICAS Fuel Information Display
Figure 12-19
Interior Optional FUEL/DEFUEL Panel
Figure 12-20
P604_12_016
BRT BRT
0.0
0.0
0.0
0.0
0 0
N1
90.0
ITT
N2
DN DN DN
- GEAR - - FLAPS -
C ALT
STAB
RATE
- TRIM -
P
3200 200 -0.5
0
NU
ND 0.8
RUDDER
AIL
LWD RWD
NL NR
FF
OIL PRESS
OIL TEMP
FAN VIB
7140 4870
19990
0.0
16
0
0
3100
- FUEL (LBS) - TOTAL
0
0
15
0.0
4870
NOSE DOOR OPEN
R ENG OIL PRESS
L ENG OIL PRESS
INBD BRAKE PRESS
OUTBD BRAKE PRESS
R FUEL LO PRESS
L FUEL LO PRESS
L FUEL PUMP
R FUEL PUMP
YAW DAMPER
STAB TRIM
R PROBE HEAT OFF
L PROBE HEAT OFF
HYD 3 LO PRESS
HYD 2 LO PRESS
HYD 1 LO PRESS
GND SPLRS
PAGE 1/2
FF ( )
OIL PRESS
OIL TEMP
FAN VIB
7160 4870
20000
0.0
16
82
3500
3140
- FUEL ( ) - TOTAL
3500
0
15
0.0
4870
NO FUEL DATA
BRT BRT
EICAS DISPLAY 2 (ED 2)
GND SPLR DEPLOY
FLT SPLR DEPLOY
FLAPS MOTOR OVHT
CABIN TEMP
BLEED PRESS
FUEL TEMP
ENGINE
BULK
OXY
C ALT
RATE
P
50
20
48
70 75
-20
2000
3200
200
SPOILERS -0.5
APU
95 430
RPM EGT
Fuel
Flow
Indications
Fuel
Flow
EICAS DISPLAY 1 (ED 1)
Fuel
Temperature
Indications
Fuel
Quantity
Indicators
CL
HL HL HL
OP OP
(OPEN)
SOV
(CLOSED)
OVERRIDE
TOTAL QTY
TEST L MAIN TAIL AUX R MAIN
LAMP
SHUT-OFF
TEST
KG
CL DEF
OFF
FUEL
P604_12_014
LBS
HL
OP OP OP
CL CL CL
HIGH LEVEL DETECTOR
FUEL SYSTEM
12-32 For Training Purposes Only
Jan 04
P I LOT T R A I N I N G GU I D E
Exterior FUEL/DEFUEL Panel
Figure 12-21
Override Button
Allows individual fueling of the
auxiliary tank or tail tank,
disables the FSCU while
depressed
POWER
FUEL
OFF
DEFUEL
HIGH LEVEL SENSORS
L MAIN TAIL AUX R MAIN
OPEN
SOV
CLOSED
OVERRIDE
SHUT
OFF
TEST
Power Toggle Switch
Supplies power directly from
the APU battery direct bus to
the fuel/defuel control system.
High Level Sensor Lights
Indicates that the fuel level in
the respective tank has
reached the full capacity
SOV Open Lights
Indicates that the
respective SOVs are
open
Power Kill Switch
Removes power to fuel/defuel
panel when access panel
closed
SOV closed lights
Indicates that the respective
fuel/defuel shutoff valves
(SOV) are closed.
Shutoff Test Button
Tests automatic shutoff
during fueling
Single-Point Pressure
Fueling Adapter
Fuel/Defuel
Panel