Flow Lines (Upper)
Generator is loaded
Generator is overloaded
Generator is not on-line
Invalid data
Voltage between 100 and 125 VAC
Voltage less than 100 VAC or more than 125 VAC
Invalid data
Frequency between 375 and 425 Hz
Frequency less than 375 Hz or more than 425 Hz
Invalid data
Generator line contactor at generator position
Generator line contactor at tie position
4
36
0
- -
115
94
- - -
400
429
- - -
KVA
KVA
KVA
KVA
V
V
V
HZ
HZ
HZ
ELECTRICAL
For Training Purposes Only
May 03
7-39
P I LOT T R A I N I N G GU I D E
AC Synoptic Page Color Coding - APU Generator (1 of 2)
Figure 7-31
AC ELECTRICAL
UTIL BUS 1
BUS 2
GEN
2
GEN
1
APU
BUS 1
UTIL BUS 2
0
0
0
GEN
ESS BUS
KVA
V
HZ
0
0
0
KVA
V
HZ
6
113
400
KVA
V
HZ
P604_07_044
Description Symbol Condition
APU Outline
APU off
APU running and ready to load
Invalid data
APU Generator Outline
APU Generator Output
Flow Line (Lower)
Generator on-line
Generator off with APU running
Both respective generator and APU are off
Invalid data
Generator is on
Generator is off
GEN
GEN
GEN
GEN
APU Generator Output
Flow Line (Lower)
APU Generator Output
Flow Lines (Upper)
APU Generator
Frequency Readout
APU Generator
Voltage Readout
APU Generator
Load Readout
APU
APU
APU
ELECTRICAL
7-40 For Training Purposes Only
May 03
P I LOT T R A I N I N G GU I D E
AC Synoptic Page Color Coding - APU Generator (2 of 2)
Figure 7-32
P604_07_045
Description Symbol Condition
APU Generator
Load Readout
APU Generator
Voltage Readout
APU Generator
Frequency Readout
APU Generator Output
Flow Lines (Upper)
Generator is loaded
Generator is overloaded
Generator is not on-line
Invalid data
Voltage between 100 and 125 VAC
Voltage less than 100 VAC or more than 125 VAC
Invalid data
Frequency between 375 and 425 Hz
Frequency less than 375 Hz or more than 425 Hz
Invalid data
Generator line contactor at generator position
Generator line contactor at tie position
6
36
0
- -
113
94
- - -
400
429
- - -
KVA
KVA
KVA
KVA
V
V
V
HZ
HZ
HZ
ELECTRICAL
For Training Purposes Only
Jan 04
7-41
P I LOT T R A I N I N G GU I D E
AC Synoptic Page Color Coding - AC Electrical Power Distribution
Figure 7-33
P604_07_047
Description Symbol Condition
Bus powered
AC BUS 1, 2
Bus Bar Outline
Bus not powered
Invalid data
ESS BUS
Bus Bar Outline
Bus powered
UTIL BUS 1, 2
Bus Bar Outline
AUTO XFER OFF Icon
AUTO XFER FAIL Icon
SHED Icon
Invalid data
Bus inoperative
Bus powered
Bus not powered (shed)
Invalid data
Displayed when AUTO XFER switch/light is manually selected
Indicates that the corresponding automatic bus transfer
has failed
Displayed when AC UTIL BUS 1 and 2 are load shed
BUS 1
BUS 1
BUS 1
BUS 2
BUS 2
BUS 2
ESS BUS
ESS BUS
ESS BUS
UTIL BUS 1
UTIL BUS 1
UTIL BUS 1
UTIL BUS 2
UTIL BUS 2
UTIL BUS 2
AUTO
XFER
OFF
AUTO
XFER
FAIL
SHED
AC ELECTRICAL
BUS 2
GEN
2
GEN
1
APU
BUS 1
UTIL BUS 1 UTIL BUS 2
GEN
4
115
400
KVA
V
HZ
4
115
400
KVA
V
HZ
0
0
0
KVA
V
HZ
AUTO
XFER
OFF
ESS BUS
BUS 2
GEN
2
UTIL BUS 2
4
115
400
KVA
V
HZ
AUTO
XFER
OFF
BUS 2
GEN
2
UTIL BUS 2
0
0
0
KVA
V
HZ
AUTO
XFER
FAIL
SHED
ELECTRICAL
7-42 For Training Purposes Only
May 03
P I LOT T R A I N I N G GU I D E
AC Synoptic Page Color Coding - External AC Electrical Power
Figure 7-34
P604_07_046
Description Symbol Condition
External AC Outline
 