1500 Add 8 fluid ounces of Alodine 1500 to water for each gallon of final
solution. Stir to get a uniform mixture.
NOTE: All gallons are U.S. gallons.
When a water-break free surface cannot be obtained, Ridosol 501 wetting agent
(same source as Alodine) may be added to the solution. Add 0.10 to 0.50% by
volume, i.e. 0.128 to 0.64 fluid ounces per gallon.
Alodine Solution Preparation for Manual Application
Figure 2
Volume 1
20-50-00
Page 10
OCT 01/01
CORROSION PREVENTION MANUAL
GENERAL INFORMATION STANDARD TREATMENT METHODS
Material Variable Make-Up [1] Control
Iridite 14 Concentration pH Temperature 2.8 oz/ gal 2.7 to 3.3 oz/gal 1.0 to 1.7 [2] Room temp to 95°F
Iridite 14-2 Concentration pH Temperature 1.45 oz/gal 1.25 to 2.25 oz/ gal 1.1 to 16 [2]
Room temp to 95°F
[1] After make-up, allow the solution to set undisturbed for 24 hours before
using. The small amount of precipitate which forms will not bother the
coating process.
[2] Adjust the pH with nitric acid until a distinctly yellow adherent film is
obtained within the 5 minute immersion time on bare 2024 aluminum alloy.
Iridite Solution Preparation
Figure 3
Volume 1
20-50-00
Page 11
OCT 01/01
CORROSION PREVENTION MANUAL
GENERAL INFORMATION STANDARD TREATMENT METHODS
8. Treatment of Fasteners and Fastener Holes in Composites for Repairs
A. Graphite panel installed on graphite structural component.
(1)Remove fasteners, if loose.
(2)On countersinks and in holes, apply primer BMS 10-11 type 1 or BMS 10-79
type 2.
(3)Install removable steel or titanium fasteners dry.
(4)Install permanent fasteners with wet primer or BMS 5-95 sealant.
B. Graphite panel installed on aluminum structure, or aluminum repair plates on
graphite panels.
(1)Remove fasteners, if loose.
(2)On countersinks and in holes, apply primer BMS 10-11 type 1 or BMS 10-79
type 2.
(3)Apply BMS 5-95 fay surface sealant on mating surfaces.
(4)Install fasteners with wet BMS 5-95 sealant.
(5)Fillet seal protruding fastener heads and nuts/washers.
C. Armada or fiberglass or graphite panels, installed in any combination.
(1)Remove fasteners, if loose.
(2)On countersinks and in holes, apply primer BMS 10-11 type 1 or BMS 10-79
type 2.
(3)Install removable fasteners with wet BMS 10-11 type 1 or BMS 10-79 type
2 primer.
(4)Install permanent fasteners with wet primer or BMS 5-95 sealant.
Volume 1
20-50-00
Page 12
OCT 01/01
CORROSION PREVENTION MANUAL
GENERAL INFORMATION
STANDARD PREVENTIVE MAINTENANCE PROCEDURES
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 防腐手册 CORROSION PREVENTION MANUAL 第二册 一般信息(49)