• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-09-23 15:40来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

EFG
.

 


.
CTC-201-126-01
EFFECTIVITY
73-11-50 Page 15
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03

CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
FUEL RETURN VALVE
Recirculation to the tank is inhibited, (FRV closed), in any of the following cases:
-
When N2 speed is below 50% during engine start.

-
When the metered fuel flow is greater than 5520 pph.
(T/O power).

 

-With engine shut-down.
-When the aircraft management system sends an
inhibit signal (fuel temp high + fuel tank full).

-When flight / ground status is not available. The FRV is opened to the second level (HIGH):
- During a FADEC ground motoring test.

EFG


.
CTC-201-127-02
EFFECTIVITY
73-11-50 Page 17
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03

CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
THIS PAGE INTENTIONALLY LEFT BLANK


EFG
VARIABLE GEOMETRY CONTROL SYSTEM

EFFECTIVITY
75-30-00 Page 1
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03

CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
VARIABLE GEOMETRY CONTROL SYSTEM
The variable geometry control system is designed to maintain satisfactory compressor performance over a wide range of operation conditions.
The system consists of:
-
 A Variable Bleed Valve (VBV) system, located downstream from the booster.

-
 A Variable Stator Vane (VSV) system, located within the first stages of the HPC.


The compressor control system is commanded by the ECU and operated through HMU hydraulic signals.
At low speed, the LP compressor supplies a flow of air greater than the HP compressor can accept.
To establish a more suitable air flow, VBV’s are installed on the contour of the primary airflow stream, between the booster and the HPC.
At low speed, they are fully open and reject part of the booster discharge air into the secondary airflow, preventing the LPC from stalling.
At high speed, the VBV’s are closed.
The HPC is equipped with one Inlet Guide Vane (IGV) stage and three VSV stages.
An actuation system changes the orientation of the vanes to provide the correct angle of incidence to the air stream at the blades leading edge, improving HPC stall margins.

EFG


.
CTC-201-142-01
EFFECTIVITY
75-30-00 Page 3
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03

CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
THIS PAGE INTENTIONALLY LEFT BLANK


EFG
VARIABLE BLEED VALVE

EFFECTIVITY
75-31-00 Page 1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TRAINING MANUAL CFM56-5B ENGINE SYSTEMS 培训手册 CFM56-5B 发动机系统(62)