CFMI PROPRIETARY INFORMATION
The resulting axial movement of the piston causes rotation of the FMV, through a pushrod and bellcrank assembly.
Maximum and minimum stops, in the valve assembly, set the rotational limits of the FMV.
The resolver provides the ECU with electrical feedback of the FMV position.
73-21-18 Page 20
ENGINE SYSTEMS Jan 03

EFG

.
.


.
CTC-201-263-01
EFFECTIVITY
73-21-18 Page 21
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03


CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL

EFG
HYDROMECHANICAL UNIT
Delta P and bypass regulating system.

The Delta P valve and by-pass valves regulate a constant pressure drop across the FMV to ensure that the metered fuel flow is proportional to the FMV position.
The system consists of :
- A delta pressure detector.
-A by-pass valve.
The delta pressure detector senses the differential
pressure across the FMV.
Ps pressure (P1) acts on one side of the piston.
FMV output pressure (P2), plus force from a pre-loaded

spring, act on the other side of the piston. P1 - (P2 + spring load) = the stable position. The pre-loaded spring is calibrated to 36 psi.
At the stable position, the by-pass valve control signal is a constant value.
When changes occur in the Delta P across the FMV, the piston becomes unbalanced and moves axially.
This will either increase, or decrease, the by-pass valve control pressure. The by-pass valve piston will move to a more open, or closed position, thus increasing, or decreasing the by-passed fuel pressure.
This, in turn, will decrease or, increase the Ps flow (P1), and restore the Delta P to 36 psid.
Buffer.
There is a buffer, located between the Delta P valve and the by-pass valve.
This provides the necessary compensation to prevent speed overshoot and instability that could occur during overspeed limiter conditions.


EFG

 

..
CTC-201-264-01
EFFECTIVITY
73-21-18 Page 23
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03

CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL

EFG
HYDROMECHANICAL UNIT
Overspeed governor system.
The overspeed governor system limits the core engine speed (N2) to a maximum of 106%, in the event of a malfunction that could drive the engine into an overspeed condition.
The OSG, which is hydro-mechanical and independent of the ECU, is installed on-line with the Delta P valve and consists of :
-A flyweight device, which is an N2 detector consisting of flyweights, pivot pins, bearings, and a ball head gear. It produces a force on a governor pilot valve proportional to the square of the flyweight speed.
- A governor pilot valve, which ports either Psf, or Pb, to the Delta P valve in order to modulate the by-pass valve. The pilot valve translation depends on the flyweight force, versus a pre-loaded spring force.
 