EFG
.
CTC-201-269-01
EFFECTIVITY
73-21-18 Page 25
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03
CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
HYDROMECHANICAL UNIT
Overspeed Governor System in-speed condition.
During regular engine operation, the force of the flyweight device is not strong enough to overcome the force of the pre-loaded spring.
In this in-speed condition, the pilot valve continues to send Psf and Pb fuel pressures to the Delta P pilot valve in order to modulate the by-pass valve for normal operations.
EFG
.
.
.
CTC-201-267-01
EFFECTIVITY
73-21-18 Page 27
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03
CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
HYDROMECHANICAL UNIT
Overspeed Governor System in an overspeed condition.
When N2 reaches 98%, the flyweight force equals the spring force.
As speed continues to increase, the pilot valve moves up, slightly restricting Psf flow to the Delta P regulator.
When speed reaches the overspeed value of 106%, the Psf supply to the Delta P valve is reduced to Pb and this causes the by-pass valve to stroke further open.
More fuel is by-passed, decreasing fuel flow to the FMV and, therefore, less fuel is available for combustion.
As a result, N2 decreases until it is below the overspeed value.
When N2 returns to the normal range, the preloaded spring can now oppose the force of the flyweights, so the pilot valve moves back down and the pressure ported to the Delta P regulator is returned to Psf.
EFG
.
.
.
CTC-201-268-01
EFFECTIVITY
73-21-18 Page 29
ALL CFM56-5B ENGINES FOR A319-A320-A321
ENGINE SYSTEMS Jan 03
CFMI PROPRIETARY INFORMATION
CFM56-5B TRAINING MANUAL
EFG
HYDROMECHANICAL UNIT
Pressurizing and shut-off valve.
During engine start, the pressurizing and shut-off valve establishes a minimum Psf pressure to ensure proper operation of the regulators, and piston force margins.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TRAINING MANUAL CFM56-5B ENGINE SYSTEMS 培训手册 CFM56-5B 发动机系统(46)