AFT EQUIP CTR RACK
APU Battery Schematic
Figure 3 (Sheet 1)
A 
757 
MAINTENANCE MANUAL
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH 30-MINUTE ú
 24-31-00
 STANDBY POWER  ú ú 03 Page 10 ú Jan 28/02 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
H12738
AFT EQUIPMENT CENTER RACK
APU Battery Schematic
Figure 3 (Sheet 2)
A 
757 
MAINTENANCE MANUAL
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH EXTENDED ú
 24-31-00
 STANDBY POWER  ú ú 01 Page 11 ú Jan 28/02 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
H12744
A
757 
MAINTENANCE MANUAL
 (e)  
AIRPLANES WITH 30-MINUTE STANDBY POWER; When starting the APU, the APU start relay energizes, energizing the ABCIR. The battery charger is disconnected from the ground service bus. The battery is not charging.
 (f)  
If battery temperature exceeds 150°F (65°C), a thermal switch in the battery closes. The switch energizes the ABCIR, removing charger input power. The switch will re-open when battery temperature drops below 135°F (57°C).
 (g)  
EICAS computers monitor APU battery voltage and charging current.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-31-00
 ALL  ú ú 01 Page 12 ú Jan 28/02 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
FAULT ISOLATION/MAINT MANUAL
BATTERIES
* SEE THE WDM EQUIPMENT LIST
AIRPLANES WITH EXTENDED STANDBY POWER
Batteries - Component Index 
Figure 101 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-31-00
 ALL  ú ú 03 Page 101 ú Sep 28/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
M22024
A
757 
FAULT ISOLATION/MAINT MANUAL
* SEE THE WDM EQUIPMENT LIST
Batteries - Component Index 
Figure 101 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-31-00
 ALL  ú ú 03 Page 102 ú Sep 28/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
M22017
A 
757 FAULT ISOLATION/MAINT MANUAL 
FORWARD EQUIPMENT CENTER 
(RIGHT SIDE)
P34 PANEL 
SEE A 
P37 PANEL FORWARD EQUIPMENT CENTER ACCESS, 
MAIN113AL 
BATTERY, M223 
FORWARD 
EQUIPMENT 
CENTER
MAIN(LEFT SIDE) BATTERY 
SEE B SHUNT, 
M224 MAIN EQUIPMENT CENTER ACCESS, 119AL 
STATIC 
INVERTER 
(REF)
MAIN BATTERY 
BATTERY CURRENT 
CHARGER, MONITOR, 
M218 
M10212 FWD 
FORWARD EQUIPMENT CENTER (RIGHT SIDE) 
A 
YFMM-24-31-0002 
FWD 
FORWARD EQUIPMENT CENTER (LEFT SIDE) 
B 
Batteries - Component Location 
Figure 102 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 24-31-00
 ALL  ú ú 02 Page 103 ú Dec 20/90 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
757 FAULT ISOLATION/MAINT MANUAL
AFT EQUIPMENT CENTER RACK, E6
APU BATTERY SHUNT, M10251, IS AT ONE OF THESE LOCATIONS 
Batteries - Component Location 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 电源 ELECTRICAL POWER 2(30)