 |  Do this through the sump drain  |  |  |  |  |  |  |  |  |
 |  valves from the fuel tanks and  |  |  |  |  |  |  |  |  |
 |  surge tanks.  This will prevent  |  |  |  |  |  |  |  |  |
 |  corrosion because of water  |  |  |  |  |  |  |  |  |
 |  accumulation.  |  |  |  |  |  |  |  |  |

 ................................................................................. | 3. After 1-year, apply BMS 3-23 Type II | | X | | | | | | yr| | corrosion inhibiting compound to | | | | | | | | | | areas of the fuel system that are | | | | | | | | | | exposed to corrosion, as required. | | | | | | | | |
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 10-11-02
 ALL  ú ú 02 Page 218 ú May 20/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 ~............................................................................... | | Procedures Repeat Intervals (Days) | | ....................................... | | | | | | | | | As| | Item | Initial | 7 | 14| 30| 60| 90|180|Rqd| .................................................................................
 | WARNING: DO NOT BREATH OR TOUCH THE |_______ |  |  |  |  |  |  |  |
 | BIOCIDE FUEL ADDITIVE. IF |  |  |  |  |  |  |  |  |
 | YOU BREATH THE FUMES OR |  |  |  |  |  |  |  |  |
 | TOUCH THE BIOCIDE FUEL |  |  |  |  |  |  |  |  |
 | ADDITIVE, IT COULD KILL YOU. |  |  |  |  |  |  |  |  |
 | |  |  |  |  |  |  |  |  |
 | CAUTION: DO NOT ADD A LARGE |_______ |  |  |  |  |  |  |  |
 | CONCENTRATION OF THE BIOCIDE |  |  |  |  |  |  |  |  |
 | FUEL ADDITIVE TO THE FUEL |  |  |  |  |  |  |  |  |
 | TANKS. A LARGE CONCENTRATION |  |  |  |  |  |  |  |  |
 | OF THE FUEL ADDITIVE CAN MAKE |  |  |  |  |  |  |  |  |
 | SALT DEPOSITS IN THE FUEL |  |  |  |  |  |  |  |  |
 | TANKS. |  |  |  |  |  |  |  |  |
 | |  |  |  |  |  |  |  |  |
 | IF METERED INJECTION EQUIPMENT|  |  |  |  |  |  |  |  |
 | IS NOT AVAILABLE, REFER TO THE|  |  |  |  |  |  |  |  |
 | CORROSION PREVENTION MANUAL, |  |  |  |  |  |  |  |  |
 | CPM PART 1, SECTION 20-62-00, |  |  |  |  |  |  |  |  |
 | FOR OTHER APPROVED PROCEDURES |  |  |  |  |  |  |  |  |
 | TO ADD BIOCIDE TO THE FUEL |  |  |  |  |  |  |  |  |
 | TANKS. |  |  |  |  |  |  |  |  |
 | 4. Put the fuel additive in the fuel |  X  |  |  |  |  |  |  |  |
 | tanks. Add to the fuel, 135 to 270 |  |  |  |  |  |  |  |  |
 | parts per million of Biobor JF, or |  |  |  |  |  |  |  |  |
 | 0.05% to 0.15% by volume of PFA55MB |  |  |  |  |  |  |  |  |
 | (MIL-I-17686). Mix the additive |  |  |  |  |  |  |  |  |
 | fully, in an open area away from |  |  |  |  |  |  |  |  |
 | airplane before it is fueled. This |  |  |  |  |  |  |  |  |
 | will prevent high local |  |  |  |  |  |  |  |  |
 | concentrations of biocide. |  |  |  |  |  |  |  |  |
 | |  |  |  |  |  |  |  |  |
 | NOTE: The fuel additive will |____ |  |  |  |  |  |  |  |
 