* INVERSION OF EWD AND SD :
* ECAM UPPER DISPLAY   OFF THEN ON
The action on the EIS DMC SWITCHING selector produces the same effect.
Only the EWD is available. No SD on the other DUs.
* To call a SYS page :
* PRESS AND MAINTAIN SYS page key on the ECP.
* OVERFLOW ON THE STATUS page :
* PRESS AND MAINTAIN STS KEY ON ECP
First page of the STATUS is displayed.
* RELEASE IT, THEN PRESS IT AGAIN WITHIN 2 SECONDS
Second page of the STATUS is displayed.
* CONTINUE UNTIL THE OVERFLOW ARROW DISAPPEARS
When the STS key is released for more than 2 seconds, EWD is displayed again.A319/A320/A321
orinf,.+7
ABNORMAL PROCEDURES
REV 36
2. ii


SEQ 110
— GRAVITY GEAR EXTN handcrank   PULL AND TURN
Rotate the handle clockwise 3 turns until reaching the mechanical stop, even if resistance is felt.
— L/G lever   DOWN
— GEAR DOWN indications (if available)   CHECK
NOTE: 1. Depending on aircraft speed, the display may show the landing gear doors in the amber transit position.
2. In the event of gravity extension caused by the failure of both LGCIUs, landing gear position indications on the ECAM are lost. LDG GEAR lights the ON LDG control panel remain available, if LGCIU1 is electrically-supplied.
3. The LGCIU 2 FAULT or BRAKES BSCU CH 1(2) FAULT warning may be spuriously triggered after a gravity extension.
4. If the three green downlock arrows are not on, it is possible that the handcrank is not at the mechanical stop. Check that the handcrank is firmly against the mechanical stop.
* If successful :
Do not reset the free-fall system : This will avoid such undesirable effects as further loss of fluid, in the event of a leak, or possible landing gear unlocking, in the event of a gear selector valve jamming in the UP position.
NOTE: The free-fall system may be reset in flights used for training. If the green hydraulic system is available, resetting the free-fall system allows the landing gear doors to be closed and the nosewheel steering to operate.
The flight crew should not reset the free-fall system on the ground after flight.
* If unsuccessful : — LDG WITH ABNORMAL L/G procedure   APPLY

A319/A320/A321
oniatTril.,,
ABNORMAL PROCEDURES
REV 34
2. 12


SEQ 001
PREPARATION
* CABIN CREW   NOTIFY
* ATC   NOTIFY
* GALLEY   OFF
. Consider fuel reduction to a safe minimum.
* If NOSE L/G abnormal
* CG location (if possible)   AFT
. 10 PAX from front to rear + 4 %.
. 10 PAX from mid to rear + 2.5 %.
* If one MAIN L/G abnormal

* FUEL IMBALANCE
  CONSIDER
. Open the fuel X-FEED valve and switch off the pumps on the side with landing gear normally extended.
* OXYGEN CREW SUPPLY   OFF
* SEAT BELTS/NO SMOKING   ON
* CABIN and COCKPIT   PREPARE
. Loose equipment secured.
. Survival equipment prepared.
. Belts and shoulder harness locked.
APPROACH
* GPWS SYS   OFF
* L/G LEVER   CHECK DOWN
* GRVTY GEAR EXTN handcrank   TURN BACK TO NORMAL
* AUTOBRAKE   DO NOT ARM
* EMER EXIT LT   ON
* CABIN REPORT   OBTAIN
* If one or both MAIN L/G abnormal
* A/SKID Et NW STRG   OFF
* MAX BRAKE PR   1000PSI
* GROUND SPOILERS   DO NOT ARM
BEFORE LANDING
* RAM AIR   ON
* BRACE FOR IMPACT   ORDER
Cont'd

A319/A320/A321
oniatTril.,,
ABNORMAL PROCEDURES
REV 36
2. ii


SEQ 200
— GRAVITY GEAR EXTN handcrank   PULL AND TURN
Rotate the handle clockwise 3 turns until reaching the mechanical stop, even if resistance is felt.
— L/G lever   DOWN
— GEAR DOWN indications (if available)   CHECK
NOTE: 1. Depending on aircraft speed, the display may show the landing gear doors in the amber transit position.
2. In the event of gravity extension caused by the failure of both LGCIUs, landing gear position indications on the ECAM are lost. LDG GEAR lights the ON LDG control panel remain available, if LGCIU1 is electrically-supplied.
3. The LGCIU 2 FAULT or BRAKES SYS 1(2) FAULT warning may be spuriously triggered after a gravity extension.
4. If the three green downlock arrows are not on, it is possible that the handcrank is not at the mechanical stop. Check that the handcrank is firmly against the mechanical stop.
* If successful :
Do not reset the free-fall system : This will avoid such undesirable effects as further loss of fluid, in the event of a leak, or possible landing gear unlocking, in the event of a gear selector valve jamming in the UP position.
NOTE: The free-fall system may be reset in flights used for training. If the green hydraulic system is available, resetting the free-fall system allows the landing gear doors to be closed and the nosewheel steering to operate.
 