L1 FWD CRG COOLING................................................................................................................... OFF
L2 (These lines are only displayed, if the automatic closure of the cargo cooling cold air valve is not
operative.)
L1  WHEN PACK OVHT OUT:
PACK (AFFECTED)..................................................................................................................ON
FWD CRG COOLING ............................................................................................................. ON
L2 (These lines are only displayed, if the automatic closure of the cargo cooling cold air valve is
not operative.)
To be continued on next page
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
AIR CONDITIONING / PRESSURIZATION / VENTILATION
A330/A340 FLEET PRO-ABN-21 P 5/70
FCOM 19 AUG 10
AIR PACK 1(2) OVHT (Cont'd)
L12
STATUS
 WHEN PACK OVHT OUT:
PACK (AFFECTED)............................................................ON
FWD CRG COOLING ........................................................ON
(These lines are only displayed, if the forward cargo cooling
is installed and if the automatic closure of the cargo cooling
cold air valve is not operative.)
INOP SYS
PACK 1(2)
L12
STATUS
 WHEN PACK OVHT OUT:
PACK (AFFECTED)............................................................ON
FWD CRG COOLING ........................................................ON
(These lines are only displayed, if the automatic closure of
the cargo cooling cold air valve is not operative.)
INOP SYS
PACK 1(2)
FWD CRG TEMP
AIR PACK VALVE 1(2) FAULT
Applicable to:
 If only one PACK VALVE closed (on ground at engine start):
PACK (affected) INHIB BY DOORS
L2 In case of prevention of pressurization due to one door not closed, only one pack valve is
closed. The valve of the other pack stays abnormally in the OPEN position.
L1 FWD CRG COOLING ............................................................................................................OFF
L2 (These lines are only displayed, if the forward cargo cooling is installed and if the automatic
closure of the cargo cooling cold air valve is not operative.)
L1  Other cases:
PACK (AFFECTED)................................................................................................................OFF
FWD CRG COOLING ............................................................................................................OFF
L2 (These lines are only displayed, if the forward cargo cooling is installed and if the automatic
closure of the cargo cooling cold air valve is not operative.)
To be continued on next page
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
AIR CONDITIONING / PRESSURIZATION / VENTILATION
A330/A340 FLEET PRO-ABN-21 P 6/70
FCOM 19 AUG 10
AIR PACK VALVE 1(2) FAULT (Cont'd)
STATUS
INOP SYS
PACK 1(2)
FWD CRG TEMP
AIR PACK VALVE 1(2) FAULT
Applicable to:
 If only one PACK VALVE closed (on ground at engine start):
PACK (affected) INHIB BY DOORS
L2 In case of prevention of pressurization due to one door not closed, only one pack valve is
closed. The valve of the other pack stays abnormally in the OPEN position.
L1 FWD CRG COOLING ............................................................................................................OFF
L2 (These lines are only displayed, if the forward cargo cooling is installed and if the automatic
closure of the cargo cooling cold air valve is not operative.)
L1  Other cases:
PACK (AFFECTED)................................................................................................................OFF
FWD CRG COOLING ............................................................................................................OFF
L2 (These lines are only displayed, if the forward cargo cooling is installed and if the automatic
closure of the cargo cooling cold air valve is not operative.)
STATUS
INOP SYS
PACK 1(2)
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
AIR CONDITIONING / PRESSURIZATION / VENTILATION
A330/A340 FLEET PRO-ABN-21 P 7/70
FCOM 19 AUG 10
AIR PACK VALVE 1(2) FAULT
Applicable to: ,
 If only one PACK VALVE closed (on ground at engine start):
PACK (affected) INHIB BY DOORS
L2 In case of prevention of pressurization due to one door not closed, only one pack valve is
closed. The valve of the other pack stays abnormally in the OPEN position.