Indicates that the respective generator is not operating. This message will be red if
both generators are inoperative.
1. Electrical Load - - - - - - - - - - - - - - - - - - - - - - - - - - REDUCE AS REQUIRED
(300 A maximum < FL300/280 A > FL300)
2. AIR COND Switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - OFF
3. GEN Switch (affected side) - - - - - - - - - - - - - - - - - - - - - -RESET; THEN OFF
4. Generator Volts - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CHECK
• IF VOLTAGE IS APPROXIMATELY 28 VOLTS
5. GEN Switch (affected side) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ON
6. Generator Amps- - - - - - - - - - - - - - - - VERIFY GENERATOR ON LINE
IF GENERATOR DOES NOT COME ON LINE
7. GEN Switch (affected side) - - - - - - - - - - - - - - - - - - - - - - - - - - OFF
8. Electrical Load - - - - - - - - - - -MONITOR; REDUCE AS REQUIRED
(300 A maximum < FL300/280 A > FL300)
C A U T I O NCAUTION
To avoid the possibility of ice shedding from the inoperative windshield and
entering the engine, avoid entering or exit icing conditions as required.
PROCEDURE COMPLETED
IF GENERATOR COMES ON LINE
7. AIR COND Switch- - - - - - - - - - - - - - - - - - - - - - - - - - AS DESIRED
PROCEDURE COMPLETED
• IF VOLTAGE IS ABOVE 29 VOLTS OR LESS THAN 26 VOLTS
5. GEN Switch (affected side) - - - - - - - - - - - - - - - - - - - - - - - LEAVE OFF
6. Electrical Load - - - - - - - - - - - - - -MONITOR; REDUCE AS REQUIRED
(300 A maximum < FL300/280 A > FL300)
PROCEDURE COMPLETED
3 AFT JBOX LMT L-R (AFT J-BOX LIMITER)
4 GEN OFF L-R AMBER (SINGLE GENERATOR INOPERATIVE)
510CLEAP-07 AA 49
L
Configuration
EMERGENCY/ABNORMAL PROCEDURES MODEL 510
1. AP / TRIM DISC Button - PRESS
PROCEDURE COMPLETED
1. Control Wheel- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -GRIP FIRMLY
2. AP/TRIM DISC Button (if required) - - - - - - - - - - - - - - - - - - - - - - - PRESS
(high elevator control forces possible)
3. Trim - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - AS REQUIRED USING
MANUAL TRIM WHEEL
4. Actuate each half of the pilot and copilot manual electric trim switches
separately for at least 3 seconds each.
• IF RED PTRM MESSAGE CLEARS
PROCEDURE COMPLETED
• IF RED PTRM MESSAGE REMAINS OR POSTS DURING SWITCH
ACTIVATION
5. Autopilot - - - - - - - - - - - - - - - - - - - - - - - - - - - - DO NOT RE-ENGAGE
PROCEDURE COMPLETED
Indicates a failure of the roll axis of the autopilot. The autopilot will be inoperative.
Indicates a failure of the pitch axis of the autopilot. The autopilot will be inoperative.
Indicates a failure of the yaw axis of the autopilot. The autopilot and yaw damper will
be inoperative.
1. Refer to YAW DAMPER INOPERATIVE; Tab X3.
1 AUTOPILOT MALFUNCTION (POSSIBLE RED AFCS ON PFD)
1. AP/TRIM DISC Button - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PRESS
2 PITCH TRIM FAILURE (RED PTRM ON PFD)
3 ROLL AXIS AUTOPILOT FAILURE (RED ROLL ON PFD)
4 PITCH AXIS AUTOPILOT FAILURE (RED PTCH ON PFD)
5 YAW AXIS AUTOPILOT FAILURE (RED YAW ON PFD)
50 AA 510CLEAP-07
M
Configuration
MODEL 510 EMERGENCY/ABNORMAL PROCEDURES
5. AP/TRIM DISC Button- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - RELEASE
6. Land as soon as practical. Refer to AILERON TRIM INOPERATIVE; Tab N3.
PROCEDURE COMPLETED
.
4. AP/TRIM DISC Button- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - RELEASE
5. Land as soon as practical. Refer to RUDDER TRIM INOPERATIVE; Tab N4.
PROCEDURE COMPLETED
5. AP/TRIM DISC Button- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - RELEASE
6. Land as soon as practical.
PROCEDURE COMPLETED
6 AILERON TRIM RUNAWAY
1. Control Wheel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - GRIP FIRMLY
2. AP/TRIM DISC Button- - - - - - - - - - - - - - - - - - - - - - - PRESS AND HOLD
(high aileron control forces possible)
3. Airspeed - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -REDUCE
(as required to minimize control forces)
4. AILERON TRIM Circuit Breaker (left circuit breaker panel) - - - - - - - PULL
7 RUDDER TRIM RUNAWAY
1. RUDDER PEDALS - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOLD FIRMLY
2. AP/TRIM DISC Button- - - - - - - - - - - - - - - - - - - - - - - PRESS AND HOLD
(high rudder control forces possible)
3. RUDDER TRIM Circuit Breaker (left circuit breaker panel) - - - - - - - PULL
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
Citation Mustang checklist EMERGENCY/ABNORMAL PROCEDURES(27)